All Downloads are FREE. Search and download functionalities are using the official Maven repository.

edits.seer.internal.rules.IF79_3.xml Maven / Gradle / Ivy

There is a newer version: 024-13
Show newest version
        <rule id="IF79_3" name="RX Summ--Scope Reg 98-02,Site,Rpt,ICDO3 (SEER IF79)" tag="N0802" java-path="lines.line" category="inter-field" depends="Histologic_Type_ICD-O-3,Primary_Site,RX_Summ--Scope_Reg_98-02,Year_of_Diagnosis">
            <expression><![CDATA[if (line.rxSummScopeReg9802 == null || line.histologicTypeIcdO3 == null)
    return true
if ((line.dateOfDiagnosisYear < '2000' || line.dateOfDiagnosisYear ==  null) && ['0000001544', '0000001563'].contains(line.registryId))
    return true

if (line.typeOfReportingSource == '6') {
    if (Functions.matches(line.primarySite, /^C(700|71\d|809)$/) || Functions.between(line.histologicTypeIcdO3, '9590', '9989'))
        return (line.rxSummScopeReg9802 == '0' || line.rxSummScopeReg9802 == '9')
    return line.rxSummScopeReg9802 == '0'
}
if (line.typeOfReportingSource == '7')
    return line.rxSummScopeReg9802 == '9'

Integer site = Functions.asInt(line.primarySite.substring(1))
return ((List)((Map)Context.IF79SiteReferenceTable).getOrDefault(site, [])).contains(Functions.asInt(line.rxSummScopeReg9802))]]></expression>
            <message>RX Summ--Scope reg 98-02 and Primary Site conflict (ICD-O-3)</message>
            <description><![CDATA[This edit is skipped under the following conditions:
    1.  Year of Date of Diagnosis is less than 2000 and Registry ID
        is equal to 0000001544 (New Jersey) or 0000001563 (Massachusetts)
    2.  RX Summ--Scope Reg 98-02 is blank
    3.  Histologic Type ICD-O-3 is blank

1.  If Type of Reporting Source is 6 (autopsy only)
    A.  For Primary Site of brain (C700, C710-C719), unknown site (C809),
        lymphoma and hematopoietic (Histologic Type ICD-O-3 = 9590-9989),
        RX Summ--Scope Reg 98-02 must specify none (0) or unknown (9)
    B.  For all other sites/histologies, RX Summ--Scope Reg 98-02
        must specify none (0).

2.  If Type of Reporting Source is 7 (death certificate only),
    then RX Summ--Scope Reg 98-02 must be 9 (unknown).

3.  For all other values of Type of Reporting Source:
    The valid RX Summ--Scope Reg 98-02 codes for each Primary Site are
    specified in Appendix C of the SEER Program Code Manual, 3rd Edition.]]></description>
            <history>
                <event version="SE12-002-01" user="murphyr" date="2009-12-21">Edit now skipped if registry is new jersey and year of diagnosis is blank.</event>
                <event version="SE16-016-08" user="depryf" date="2017-11-22" ref="67674">Edit syntax updated to allow pre-compilation optimization; no change in behavior.</event>
                <event version="SE18-018-02" user="schadega" date="2018-05-25" ref="67760">Edit name change.</event>
                <event version="SE18-019-02" user="kirbyk" date="2019-05-16" ref="68185">Updated documentation; no change in behavior.</event>
                <event version="SE18-020-01" user="depryf" date="2020-02-04" ref="68281">Changed property names to align with NAACCR XML IDs.</event>
                <event version="SE18-020-05" user="beverung" date="2020-09-04" ref="68521">Added 0000001563 (Massachusetts) to skip condition.</event>
                <event version="SE24-024-06" user="kirbyk" date="2024-07-22" ref="69326">Removed some edit dependencies.</event>
            </history>
        </rule>




© 2015 - 2024 Weber Informatics LLC | Privacy Policy