net.wimpi.modbus.Modbus Maven / Gradle / Ivy

Go to download

jamod is an object oriented implementation of the Modbus protocol, realized 100% in Java. It allows to quickly realize master and slave applications in various transport flavors (IP and serial).

The newest version!
/***
 * Copyright 2002-2010 jamod development team
 *
 * Licensed under the Apache License, Version 2.0 (the "License");
 * you may not use this file except in compliance with the License.
 * You may obtain a copy of the License at
 *
 * http://www.apache.org/licenses/LICENSE-2.0
 *
 * Unless required by applicable law or agreed to in writing, software
 * distributed under the License is distributed on an "AS IS" BASIS,
 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
 * See the License for the specific language governing permissions and
 * limitations under the License.
 ***/

package net.wimpi.modbus;

/**
 * Interface defining all constants related to the
 * Modbus protocol.
 *
 * @author Dieter Wimberger
 * @version 1.2 (@date@)
 */
public interface Modbus {


  /**
   * JVM flag for debug mode. Can be set passing the system property
   * net.wimpi.modbus.debug=false|true (-D flag to the jvm).
   */
  public static final boolean debug = "true".equals(System.getProperty("net.wimpi.modbus.debug"));
  
  /**
   * Defines the class 0 function code
   * for read multiple registers.
   */
  public static final int READ_MULTIPLE_REGISTERS = 3;

  /**
   * Defines the class 0 function code
   * for write multiple registers.
   */
  public static final int WRITE_MULTIPLE_REGISTERS = 16;

  /**
   * Defines the class 1 function code
   * for read coils.
   */
  public static final int READ_COILS = 1;

  /**
   * Defines a class 1 function code
   * for read input discretes.
   */
  public static final int READ_INPUT_DISCRETES = 2;

  /**
   * Defines a class 1 function code
   * for read input registers.
   */
  public static final int READ_INPUT_REGISTERS = 4;

  /**
   * Defines a class 1 function code
   * for write coil.
   */
  public static final int WRITE_COIL = 5;

  /**
   * Defines a standard function code
   * for write multiple coils.
   */
  public static final int WRITE_MULTIPLE_COILS = 15;

  /**
   * Defines a class 1 function code
   * for write single register.
   */
  public static final int WRITE_SINGLE_REGISTER = 6;

  /**
   * Defines the byte representation of the coil state on.
   */
  public static final int COIL_ON = (byte) 255;

  /**
   * Defines the byte representation of the coil state pos.
   */
  public static final int COIL_OFF = 0;

  /**
   * Defines the word representation of the coil state on.
   */
  public static final byte[] COIL_ON_BYTES = {(byte) COIL_ON, (byte) COIL_OFF};

  /**
   * Defines the word representation of the coil state pos.
   */
  public static final byte[] COIL_OFF_BYTES = {(byte) COIL_OFF, (byte) COIL_OFF};

  /**
   * Defines the maximum number of bits in multiple read/write
   * of input discretes or coils (2000).
   */
  public static final int MAX_BITS = 2000;

  /**
   * Defines the Modbus slave exception offset that is added to the
   * function code, to flag an exception.
   */
  public static final int EXCEPTION_OFFSET = 128;			//the last valid function code is 127

  /**
   * Defines the Modbus slave exception type illegal function.
   * This exception code is returned if the slave:
   * 
    *
  • does not implement the function code or
  • *
  • is not in a state that allows it to process the function
  • *
*/ public static final int ILLEGAL_FUNCTION_EXCEPTION = 1; /** * Defines the Modbus slave exception type illegal data address. * This exception code is returned if the reference: *
    *
  • does not exist on the slave or
  • *
  • the combination of reference and length exceeds the bounds * of the existing registers. *
  • *
*/ public static final int ILLEGAL_ADDRESS_EXCEPTION = 2; /** * Defines the Modbus slave exception type illegal data value. * This exception code indicates a fault in the structure of the data values * of a complex request, such as an incorrect implied length.
* This code does not indicate a problem with application specific validity * of the value. */ public static final int ILLEGAL_VALUE_EXCEPTION = 3; /** * Defines the default port number of Modbus * (=502). */ public static final int DEFAULT_PORT = 502; /** * Defines the maximum message length for serial transport in bytes * (=256). * RS232 / RS485 ADU = 253 bytes + Server address (1 byte) + CRC (2 bytes) = 256 bytes. */ public static final int MAX_MESSAGE_LENGTH = 256; /** * Defines the maximum message length for IP transport in bytes * (=260). * TCP MODBUS ADU = 253 bytes + MBAP (7 bytes) = 260 bytes. */ public static final int MAX_IP_MESSAGE_LENGTH = 260; /** * Defines the default transaction identifier (=0). */ public static final int DEFAULT_TRANSACTION_ID = 0; /** * Defines the default protocol identifier (=0). */ public static final int DEFAULT_PROTOCOL_ID = 0; /** * Defines the default unit identifier (=0). */ public static final int DEFAULT_UNIT_ID = 0; /** * Defines the default setting for validity checking * in transactions (=true). */ public static final boolean DEFAULT_VALIDITYCHECK = true; /** * Defines the default setting for I/O operation timeouts * in milliseconds (=3000). */ public static final int DEFAULT_TIMEOUT = 3000; /** * Defines the default reconnecting setting for * transactions (=false). */ public static final boolean DEFAULT_RECONNECTING = false; /** * Defines the default amount of retires for opening * a connection (=3). */ public static final int DEFAULT_RETRIES = 3; /** * Defines the default number of msec to delay before transmission * (=50). */ public static final int DEFAULT_TRANSMIT_DELAY = 0; /** * Defines the maximum value of the transaction identifier. */ public static final int MAX_TRANSACTION_ID = (Short.MAX_VALUE * 2) - 1; /** * Defines the serial encoding "ASCII". */ public static final String SERIAL_ENCODING_ASCII = "ascii"; /** * Defines the serial encoding "RTU". */ public static final String SERIAL_ENCODING_RTU = "rtu"; /** * Defines the serial encoding "BIN". */ public static final String SERIAL_ENCODING_BIN = "bin"; /** * Defines the default serial encoding (ASCII). */ public static final String DEFAULT_SERIAL_ENCODING = SERIAL_ENCODING_ASCII; }//class Modbus