jamod is an object oriented implementation of the Modbus protocol, realized 100% in Java. It allows to quickly
realize master and slave applications in various transport flavors (IP and serial).
The newest version!
/***
* Copyright 2002-2010 jamod development team
*
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
***/
package net.wimpi.modbus;
/**
* Interface defining all constants related to the
* Modbus protocol.
*
* @author Dieter Wimberger
* @version 1.2 (@date@)
*/
public interface Modbus {
/**
* JVM flag for debug mode. Can be set passing the system property
* net.wimpi.modbus.debug=false|true (-D flag to the jvm).
*/
public static final boolean debug = "true".equals(System.getProperty("net.wimpi.modbus.debug"));
/**
* Defines the class 0 function code
* for read multiple registers.
*/
public static final int READ_MULTIPLE_REGISTERS = 3;
/**
* Defines the class 0 function code
* for write multiple registers.
*/
public static final int WRITE_MULTIPLE_REGISTERS = 16;
/**
* Defines the class 1 function code
* for read coils.
*/
public static final int READ_COILS = 1;
/**
* Defines a class 1 function code
* for read input discretes.
*/
public static final int READ_INPUT_DISCRETES = 2;
/**
* Defines a class 1 function code
* for read input registers.
*/
public static final int READ_INPUT_REGISTERS = 4;
/**
* Defines a class 1 function code
* for write coil.
*/
public static final int WRITE_COIL = 5;
/**
* Defines a standard function code
* for write multiple coils.
*/
public static final int WRITE_MULTIPLE_COILS = 15;
/**
* Defines a class 1 function code
* for write single register.
*/
public static final int WRITE_SINGLE_REGISTER = 6;
/**
* Defines the byte representation of the coil state on.
*/
public static final int COIL_ON = (byte) 255;
/**
* Defines the byte representation of the coil state pos.
*/
public static final int COIL_OFF = 0;
/**
* Defines the word representation of the coil state on.
*/
public static final byte[] COIL_ON_BYTES = {(byte) COIL_ON, (byte) COIL_OFF};
/**
* Defines the word representation of the coil state pos.
*/
public static final byte[] COIL_OFF_BYTES = {(byte) COIL_OFF, (byte) COIL_OFF};
/**
* Defines the maximum number of bits in multiple read/write
* of input discretes or coils (2000).
*/
public static final int MAX_BITS = 2000;
/**
* Defines the Modbus slave exception offset that is added to the
* function code, to flag an exception.
*/
public static final int EXCEPTION_OFFSET = 128; //the last valid function code is 127
/**
* Defines the Modbus slave exception type illegal function.
* This exception code is returned if the slave:
*
* - does not implement the function code or
* - is not in a state that allows it to process the function
*
*/
public static final int ILLEGAL_FUNCTION_EXCEPTION = 1;
/**
* Defines the Modbus slave exception type illegal data address.
* This exception code is returned if the reference:
*
* - does not exist on the slave or
* - the combination of reference and length exceeds the bounds
* of the existing registers.
*
*
*/
public static final int ILLEGAL_ADDRESS_EXCEPTION = 2;
/**
* Defines the Modbus slave exception type illegal data value.
* This exception code indicates a fault in the structure of the data values
* of a complex request, such as an incorrect implied length.
* This code does not indicate a problem with application specific validity
* of the value.
*/
public static final int ILLEGAL_VALUE_EXCEPTION = 3;
/**
* Defines the default port number of Modbus
* (=502).
*/
public static final int DEFAULT_PORT = 502;
/**
* Defines the maximum message length for serial transport in bytes
* (=256).
* RS232 / RS485 ADU = 253 bytes + Server address (1 byte) + CRC (2 bytes) = 256 bytes.
*/
public static final int MAX_MESSAGE_LENGTH = 256;
/**
* Defines the maximum message length for IP transport in bytes
* (=260).
* TCP MODBUS ADU = 253 bytes + MBAP (7 bytes) = 260 bytes.
*/
public static final int MAX_IP_MESSAGE_LENGTH = 260;
/**
* Defines the default transaction identifier (=0).
*/
public static final int DEFAULT_TRANSACTION_ID = 0;
/**
* Defines the default protocol identifier (=0).
*/
public static final int DEFAULT_PROTOCOL_ID = 0;
/**
* Defines the default unit identifier (=0).
*/
public static final int DEFAULT_UNIT_ID = 0;
/**
* Defines the default setting for validity checking
* in transactions (=true).
*/
public static final boolean DEFAULT_VALIDITYCHECK = true;
/**
* Defines the default setting for I/O operation timeouts
* in milliseconds (=3000).
*/
public static final int DEFAULT_TIMEOUT = 3000;
/**
* Defines the default reconnecting setting for
* transactions (=false).
*/
public static final boolean DEFAULT_RECONNECTING = false;
/**
* Defines the default amount of retires for opening
* a connection (=3).
*/
public static final int DEFAULT_RETRIES = 3;
/**
* Defines the default number of msec to delay before transmission
* (=50).
*/
public static final int DEFAULT_TRANSMIT_DELAY = 0;
/**
* Defines the maximum value of the transaction identifier.
*/
public static final int MAX_TRANSACTION_ID = (Short.MAX_VALUE * 2) - 1;
/**
* Defines the serial encoding "ASCII".
*/
public static final String SERIAL_ENCODING_ASCII = "ascii";
/**
* Defines the serial encoding "RTU".
*/
public static final String SERIAL_ENCODING_RTU = "rtu";
/**
* Defines the serial encoding "BIN".
*/
public static final String SERIAL_ENCODING_BIN = "bin";
/**
* Defines the default serial encoding (ASCII).
*/
public static final String DEFAULT_SERIAL_ENCODING = SERIAL_ENCODING_ASCII;
}//class Modbus