All Downloads are FREE. Search and download functionalities are using the official Maven repository.

net.wimpi.modbus.io.ModbusTCPTransport Maven / Gradle / Ivy

Go to download

jamod is an object oriented implementation of the Modbus protocol, realized 100% in Java. It allows to quickly realize master and slave applications in various transport flavors (IP and serial).

The newest version!
/***
 * Copyright 2002-2010 jamod development team
 *
 * Licensed under the Apache License, Version 2.0 (the "License");
 * you may not use this file except in compliance with the License.
 * You may obtain a copy of the License at
 *
 * http://www.apache.org/licenses/LICENSE-2.0
 *
 * Unless required by applicable law or agreed to in writing, software
 * distributed under the License is distributed on an "AS IS" BASIS,
 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
 * See the License for the specific language governing permissions and
 * limitations under the License.
 ***/

package net.wimpi.modbus.io;

import java.io.BufferedInputStream;
import java.io.BufferedOutputStream;
import java.io.DataInputStream;
import java.io.DataOutput;
import java.io.DataOutputStream;
import java.io.EOFException;
import java.io.IOException;
import java.net.Socket;
import java.net.SocketException;

import net.wimpi.modbus.Modbus;
import net.wimpi.modbus.ModbusIOException;
import net.wimpi.modbus.msg.ModbusMessage;
import net.wimpi.modbus.msg.ModbusRequest;
import net.wimpi.modbus.msg.ModbusResponse;
import net.wimpi.modbus.util.ModbusUtil;

/**
 * Class that implements the Modbus transport
 * flavor.
 *
 * @author Dieter Wimberger
 * @version 1.2 (@date@)
 */
public class ModbusTCPTransport
    implements ModbusTransport {

  //instance attributes
  private DataInputStream m_Input;	  //input stream
  private DataOutputStream m_Output;	 //output stream
  private BytesInputStream m_ByteIn;

  /**
   * Constructs a new ModbusTransport instance,
   * for a given Socket.
   * 

* @param socket the Socket used for message transport. */ public ModbusTCPTransport(Socket socket) { try { setSocket(socket); } catch (IOException ex) { if(Modbus.debug) System.out.println("ModbusTCPTransport::Socket invalid."); //@commentstart@ throw new IllegalStateException("Socket invalid."); //@commentend@ } }//constructor /** * Sets the Socket used for message transport and * prepares the streams used for the actual I/O. * * @param socket the Socket used for message transport. * @throws IOException if an I/O related error occurs. */ public void setSocket(Socket socket) throws IOException { prepareStreams(socket); }//setSocket public void close() throws IOException { m_Input.close(); m_Output.close(); }//close public void writeMessage(ModbusMessage msg) throws ModbusIOException { try { msg.writeTo((DataOutput) m_Output); m_Output.flush(); //write more sophisticated exception handling } catch (Exception ex) { throw new ModbusIOException("I/O exception - failed to write."); } }//write public ModbusRequest readRequest() throws ModbusIOException { //System.out.println("readRequest()"); try { ModbusRequest req = null; synchronized (m_ByteIn) { //use same buffer byte[] buffer = m_ByteIn.getBuffer(); //read to byte length of message if (m_Input.read(buffer, 0, 6) == -1) { throw new EOFException("Premature end of stream (Header truncated)."); } //extract length of bytes following in message int bf = ModbusUtil.registerToShort(buffer, 4); //read rest if (m_Input.read(buffer, 6, bf) == -1) { throw new ModbusIOException("Premature end of stream (Message truncated)."); } m_ByteIn.reset(buffer, (6 + bf)); m_ByteIn.skip(7); int functionCode = m_ByteIn.readUnsignedByte(); m_ByteIn.reset(); req = ModbusRequest.createModbusRequest(functionCode); req.readFrom(m_ByteIn); } return req; /* int transactionID = m_Input.readUnsignedShort(); int protocolID = m_Input.readUnsignedShort(); int dataLength = m_Input.readUnsignedShort(); if (protocolID != Modbus.DEFAULT_PROTOCOL_ID || dataLength > 256) { throw new ModbusIOException(); } int unitID = m_Input.readUnsignedByte(); int functionCode = m_Input.readUnsignedByte(); ModbusRequest request = ModbusRequest.createModbusRequest(functionCode, m_Input, false); if (request instanceof IllegalFunctionRequest) { //skip rest of bytes for (int i = 0; i < dataLength - 2; i++) { m_Input.readByte(); } } //set read parameters request.setTransactionID(transactionID); request.setProtocolID(protocolID); request.setUnitID(unitID); return request; */ } catch (EOFException eoex) { throw new ModbusIOException(true); } catch (SocketException sockex) { //connection reset by peer, also EOF throw new ModbusIOException(true); } catch (Exception ex) { ex.printStackTrace(); throw new ModbusIOException("I/O exception - failed to read."); } }//readRequest public ModbusResponse readResponse() throws ModbusIOException { //System.out.println("readResponse()"); try { ModbusResponse res = null; synchronized (m_ByteIn) { //use same buffer byte[] buffer = m_ByteIn.getBuffer(); //read to byte length of message if (m_Input.read(buffer, 0, 6) == -1) { throw new ModbusIOException("Premature end of stream (Header truncated)."); } //extract length of bytes following in message int bf = ModbusUtil.registerToShort(buffer, 4); //read rest if (m_Input.read(buffer, 6, bf) == -1) { throw new ModbusIOException("Premature end of stream (Message truncated)."); } m_ByteIn.reset(buffer, (6 + bf)); m_ByteIn.skip(7); int functionCode = m_ByteIn.readUnsignedByte(); m_ByteIn.reset(); res = ModbusResponse.createModbusResponse(functionCode); res.readFrom(m_ByteIn); } return res; /* try { int transactionID = m_Input.readUnsignedShort(); //System.out.println("Read tid="+transactionID); int protocolID = m_Input.readUnsignedShort(); //System.out.println("Read pid="+protocolID); int dataLength = m_Input.readUnsignedShort(); //System.out.println("Read length="+dataLength); int unitID = m_Input.readUnsignedByte(); //System.out.println("Read uid="+unitID); int functionCode = m_Input.readUnsignedByte(); //System.out.println("Read fc="+functionCode); ModbusResponse response = ModbusResponse.createModbusResponse(functionCode, m_Input, false); if (response instanceof ExceptionResponse) { //skip rest of bytes for (int i = 0; i < dataLength - 2; i++) { m_Input.readByte(); } } //set read parameters response.setTransactionID(transactionID); response.setProtocolID(protocolID); response.setUnitID(unitID); return response; */ } catch (Exception ex) { ex.printStackTrace(); throw new ModbusIOException("I/O exception - failed to read."); } }//readResponse /** * Prepares the input and output streams of this * ModbusTCPTransport instance based on the given * socket. * * @param socket the socket used for communications. * @throws IOException if an I/O related error occurs. */ private void prepareStreams(Socket socket) throws IOException { m_Input = new DataInputStream( new BufferedInputStream(socket.getInputStream()) ); m_Output = new DataOutputStream( new BufferedOutputStream(socket.getOutputStream()) ); m_ByteIn = new BytesInputStream(Modbus.MAX_IP_MESSAGE_LENGTH); }//prepareStreams }//class ModbusTCPTransport