All Downloads are FREE. Search and download functionalities are using the official Maven repository.

net.wimpi.modbus.msg.ModbusResponse Maven / Gradle / Ivy

Go to download

jamod is an object oriented implementation of the Modbus protocol, realized 100% in Java. It allows to quickly realize master and slave applications in various transport flavors (IP and serial).

The newest version!
/***
 * Copyright 2002-2010 jamod development team
 *
 * Licensed under the Apache License, Version 2.0 (the "License");
 * you may not use this file except in compliance with the License.
 * You may obtain a copy of the License at
 *
 * http://www.apache.org/licenses/LICENSE-2.0
 *
 * Unless required by applicable law or agreed to in writing, software
 * distributed under the License is distributed on an "AS IS" BASIS,
 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
 * See the License for the specific language governing permissions and
 * limitations under the License.
 ***/

package net.wimpi.modbus.msg;

import java.io.ByteArrayInputStream;
import java.io.DataInputStream;
import java.io.IOException;

import net.wimpi.modbus.Modbus;

/**
 * Abstract class implementing a ModbusResponse.
 * This class provides specialised implementations with
 * the functionality they have in common.
 *
 * @author Dieter Wimberger
 * @version 1.2 (@date@)
 */
public abstract class ModbusResponse
    extends ModbusMessageImpl {


  /**
   * Utility method to set the raw data of the message.
   * Should not be used except under rare circumstances.
   * 

* @param msg the byte[] resembling the raw modbus * response message. */ protected void setMessage(byte[] msg) { try { readData( new DataInputStream( new ByteArrayInputStream(msg) ) ); } catch (IOException ex) { } }//setMessage /** * Factory method creating the required specialized ModbusResponse * instance. * * @param functionCode the function code of the response as int. * @return a ModbusResponse instance specific for the given function code. */ public static ModbusResponse createModbusResponse(int functionCode) { ModbusResponse response = null; switch (functionCode) { case Modbus.READ_MULTIPLE_REGISTERS: response = new ReadMultipleRegistersResponse(); break; case Modbus.READ_INPUT_DISCRETES: response = new ReadInputDiscretesResponse(); break; case Modbus.READ_INPUT_REGISTERS: response = new ReadInputRegistersResponse(); break; case Modbus.READ_COILS: response = new ReadCoilsResponse(); break; case Modbus.WRITE_MULTIPLE_REGISTERS: response = new WriteMultipleRegistersResponse(); break; case Modbus.WRITE_SINGLE_REGISTER: response = new WriteSingleRegisterResponse(); break; case Modbus.WRITE_COIL: response = new WriteCoilResponse(); break; case Modbus.WRITE_MULTIPLE_COILS: response = new WriteMultipleCoilsResponse(); break; default: response = new ExceptionResponse(); break; } return response; }//createModbusResponse }//class ModbusResponse





© 2015 - 2024 Weber Informatics LLC | Privacy Policy