package com.intelligt.modbus.jlibmodbus;
import java.util.logging.Handler;
import java.util.logging.Level;
import java.util.logging.LogRecord;
import java.util.logging.Logger;
/*
* Copyright (C) 2016 "Invertor" Factory", JSC
* [http://www.sbp-invertor.ru]
*
* This file is part of JLibModbus.
*
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*
* Authors: Vladislav Y. Kochedykov, software engineer.
* email: [email protected]
*/
final public class Modbus {
final static public int MAX_CONNECTION_TIMEOUT = 3000;
final static public int MAX_RESPONSE_TIMEOUT = 1000;
final static public int MAX_PDU_LENGTH = 254;
/*
slave id + function code.
Note that actually the modbus pdu doesn't include the "slave id" field.
*/
final static public int MIN_PDU_LENGTH = 2;
//final static public int MAX_TCP_ADU_LENGTH = 260;
final static public int MAX_RTU_ADU_LENGTH = 256;
final static public int MAX_REGISTER_VALUE = 0xFFFF;
final static public int MIN_START_ADDRESS = 0x0000;
final static public int MAX_START_ADDRESS = 0xFFFF;
final static public int MAX_READ_COIL_COUNT = 0x7D0;
final static public int MAX_WRITE_COIL_COUNT = 0x7B0;
final static public int MAX_READ_REGISTER_COUNT = 0x7D;
final static public int MAX_WRITE_REGISTER_COUNT = 0x7B;
final static public int MAX_FIFO_COUNT = 31;
final static public int MIN_SERVER_ADDRESS = 1;
final static public int MAX_SERVER_ADDRESS = 247;
final static public int TCP_PORT = 502;
final static public int PROTOCOL_ID = 0;
final static public int TCP_DEFAULT_ID = 0xFF;
final static public int BROADCAST_ID = 0x00;
final static public int ASCII_CODE_CR = 0xd;
final static public int ASCII_CODE_LF = 0xa;
final static public int ASCII_CODE_COLON = 0x3a;
final static public int COIL_VALUE_ON = 0xff00;
final static public int COIL_VALUE_OFF = 0x0000;
final static public int TRANSACTION_ID_MAX_VALUE = 0xFFFF;
final static private Logger log = Logger.getLogger(Modbus.class.getName());
static private LogLevel logLevel = LogLevel.LEVEL_RELEASE;
static private boolean autoIncrementTransactionId = false;
/**
* the end of message delimiter, (LF character by default)
*/
static private int asciiMsgDelimiter = Modbus.ASCII_CODE_LF;
static {
setLogLevel(logLevel);
log().setUseParentHandlers(false);
log().addHandler(new Handler() {
@Override
public void publish(LogRecord record) {
System.out.println(record.getLevel().getName() + ": " + record.getMessage());
}
@Override
public void flush() {
//do nothing
}
@Override
public void close() throws SecurityException {
//do nothing
}
});
}
private Modbus() {
}
/**
* getter for the version of the library.
*
* @return a string representing the version
*/
static public String getVersion() {
return Version.getVersion();
}
static public void setAsciiInputDelimiter(int asciiMsgDelimiter) {
Modbus.asciiMsgDelimiter = asciiMsgDelimiter;
}
static public int getAsciiMsgDelimiter() {
return asciiMsgDelimiter;
}
/**
* getter for log level
*
* @return current log level
*/
static public LogLevel getLogLevel() {
return logLevel;
}
/**
* changes the log level for all loggers used
*
* @param level - LogLevel instance
* @see Modbus.LogLevel
*/
static public void setLogLevel(LogLevel level) {
logLevel = level;
log.setLevel(level.value());
for (Handler handler : log.getHandlers()) {
handler.setLevel(level.value());
}
}
static public boolean isLoggingEnabled() {
return getLogLevel() != LogLevel.LEVEL_RELEASE;
}
/**
* getter for default logger
*
* @return default logger
*/
static public Logger log() {
return log;
}
/**
* converts ON/OFF value to boolean
*
* @param s 0xFF00 of 0x0000
* @return true if s equals 0xFF00, else false
*/
static public boolean toCoil(int s) {
return (((short) s) & 0xffff) == Modbus.COIL_VALUE_ON;
}
/**
* converts boolean to ON/OFF value
*
* @param c a coil value
* @return 0xFF00 if coil value is true, else 0x0000
*/
static public int fromCoil(boolean c) {
return c ? Modbus.COIL_VALUE_ON : Modbus.COIL_VALUE_OFF;
}
/**
* validates address of server
*
* @param serverAddress - The modbus server address
* @return "true" if serverAddress is correct, else "false".
*/
static public boolean checkServerAddress(int serverAddress) {
/*
* hook for server address is equals zero:
* some of modbus tcp slaves sets the UnitId value to zero, not ignoring value in this field.
*/
switch (serverAddress) {
case 0x00:
Modbus.log().info("Broadcast message");
return true;
case 0xFF:
Modbus.log().info("0xFF default slave id using ModbusTCP");
return true;
default:
return !(serverAddress < Modbus.MIN_SERVER_ADDRESS || serverAddress > Modbus.MAX_SERVER_ADDRESS);
}
}
/**
* validates is the value in the range from min to max.
*
* @param value - the value for checkFrame
* @param min - minimum
* @param max - maximum
* @return "true" if value in the range from min to max, else "false".
*/
static private boolean checkRange(int value, int min, int max) {
return !(value < min || value > max);
}
/**
* validates the value in the range from 1 to max.
*
* @param value - the value for checkFrame
* @param max - maximum
* @return "true" if value in the range from 1 to max, else "false".
*/
static private boolean checkQuantity(int value, int max) {
return checkRange(value, 1, max);
}
/**
* validates data offset in the range from Modbus.MIN_START_ADDRESS to max.
*
* @param value - the offset for checkFrame
* @param max - maximum
* @return "true" if offset in the range from Modbus.MIN_START_ADDRESS to max, else "false".
*/
static private boolean checkStartAddress(int value, int max) {
return checkRange(value, MIN_START_ADDRESS, max);
}
/**
* validates number of registers for read
*
* @param value - register count
* @return "true" if quantity is correct, else "false".
*/
static public boolean checkReadRegisterCount(int value) {
return checkQuantity(value, Modbus.MAX_READ_REGISTER_COUNT);
}
/**
* validates number of registers for write
*
* @param value - register count
* @return "true" if quantity is correct, else "false".
*/
static public boolean checkWriteRegisterCount(int value) {
return checkQuantity(value, Modbus.MAX_WRITE_REGISTER_COUNT);
}
/**
* validates number of coils for read
*
* @param value - coil count
* @return "true" if quantity is correct, else "false".
*/
static public boolean checkReadCoilCount(int value) {
return checkQuantity(value, Modbus.MAX_READ_COIL_COUNT);
}
/**
* validates number of coils for write
*
* @param value - coil count
* @return "true" if quantity is correct, else "false".
*/
static public boolean checkWriteCoilCount(int value) {
return checkQuantity(value, Modbus.MAX_WRITE_COIL_COUNT);
}
/**
* validates start address for read/write
*
* @param value - start address
* @return "true" if start address is correct, else "false".
*/
static public boolean checkStartAddress(int value) {
return checkStartAddress(value, Modbus.MAX_START_ADDRESS);
}
/**
* validates end address for read/write
* end address = start address + quantity
*
* @param value - end address
* @return "true" if end address is correct, else "false".
*/
static public boolean checkEndAddress(int value) {
return checkStartAddress(value, Modbus.MAX_START_ADDRESS + 1);
}
/**
* validates register value
*
* @param value - value of register
* @return "true" if register value is correct, else "false".
*/
static public boolean checkRegisterValue(int value) {
return checkRange(value, 0, Modbus.MAX_REGISTER_VALUE);
}
/**
* returns autoIncrementTransactionId variable
*
* @return "true" if autoincrement of TransactionId field is enabled, else "false".
*/
public static boolean isAutoIncrementTransactionId() {
return Modbus.autoIncrementTransactionId;
}
/**
* activates auto increment of TransactionId field. if you do not use ModbusTCP, invocation has no effect.
*
* @param autoIncrementTransactionId - new value of the autoIncrementTransactionId variable
*/
public static void setAutoIncrementTransactionId(boolean autoIncrementTransactionId) {
Modbus.autoIncrementTransactionId = autoIncrementTransactionId;
}
/**
* logging.Level wrapper.
*/
public enum LogLevel {
LEVEL_RELEASE(Level.SEVERE),
LEVEL_WARNINGS(Level.WARNING),
LEVEL_VERBOSE(Level.INFO),
LEVEL_DEBUG(Level.ALL);
final private Level value;
LogLevel(Level value) {
this.value = value;
}
/**
* getter
*
* @return logging.Level instance
*/
private Level value() {
return value;
}
}
}
© 2015 - 2025 Weber Informatics LLC | Privacy Policy