        <rule id="IF454" name="CS SSF 8, Lymph Nodes, KidneyParenchyma (CS)" tag="N1775" java-path="lines.line" category="inter-field" depends="Behavior_Code_ICD-O-3,CS_Lymph_Nodes,CS_Site-Specific_Factor_8">
            <expression><![CDATA[if (line.csSiteSpecificFactor8 == null || line.csSiteSpecificFactor8 == '988' ||
    line.csLymphNodes == null || line.behaviorCodeIcdO3 == '0' || line.behaviorCodeIcdO3 == '1' ||
    line._csSchemaId != 'kidney_parenchyma')
    return true

Integer lymphNodesInt = Functions.asInt(line.csLymphNodes)
Integer ssf8Int = Functions.asInt(line.csSiteSpecificFactor8)
if (ssf8Int == 0)
    return !(lymphNodesInt >= 100 && lymphNodesInt <= 800)
if (lymphNodesInt == 0)
    return !(ssf8Int >= 10 && ssf8Int <= 30)

return true]]></expression>
            <message>CS SSF 8 and Lymph Nodes conflict for KidneyParenchyma schema</message>
            <description><![CDATA[This edit verifies that for cases using the KidneyParenchyma schema, CS SSF 8 (extranodal extension of regional lymph nodes) and CS Lymph Nodes are coded consistently.

This edit is skipped if any of the following conditions are true:
1. CS Site-Specific Factor 8 is blank or 988
2. CS Lymph Nodes is blank
3. Behavior Code ICD-O-3 = 0 (benign) or 1 (borderline)
4. CS schema is invalid

If CS schema is KidneyParenchyma:
1. If CS Site-Specific Factor 8 = 000 (no regional lymph nodes involved)
   THEN
       CS Lymph Nodes must not = 100-800 (codes indicating regional lymph node involvement)
2. If CS Lymph Nodes = 000 (no regional lymph node involvement)
   THEN
       CS Site-Specific Factor 8 must not = 010-030 (codes indicating regional lymph node involvement)

This edit first determines the correct CS schema by doing a function call to the CS Dynamic Link Library (dll).  The function call passes Primary Site, Histologic Type ICD-O-3, and CS Site-Specific Factor25 (schema discriminator) to the dll and the CS schema name is returned.]]></description>
            <history>
                <event version="SE13-010-01" user="murphyr" date="2013-05-09" ref="66869">Edit created.</event>
                <event version="SE16-015-01" user="kirbyk" date="2016-05-04" ref="67370">Changed edit to use schema IDs instead of schema names</event>
                <event version="SE16-016-08" user="depryf" date="2017-11-22" ref="67674">Edit syntax updated to allow pre-compilation optimization; no change in behavior.</event>
                <event version="SE18-020-01" user="depryf" date="2020-02-04" ref="68281">Changed property names to align with NAACCR XML IDs.</event>
            </history>
        </rule>