com.mobius.software.telco.protocols.diameter.primitives.mb2c.ROHCResult Maven / Gradle / Ivy
package com.mobius.software.telco.protocols.diameter.primitives.mb2c;
/*
* Mobius Software LTD
* Copyright 2023, Mobius Software LTD and individual contributors
* by the @authors tag.
*
* This program is free software: you can redistribute it and/or modify
* under the terms of the GNU Affero General Public License as
* published by the Free Software Foundation; either version 3 of
* the License, or (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU Affero General Public License for more details.
*
* You should have received a copy of the GNU Affero General Public License
* along with this program. If not, see
*/
import com.mobius.software.telco.protocols.diameter.TgppAvpCodes;
import com.mobius.software.telco.protocols.diameter.VendorIDs;
import com.mobius.software.telco.protocols.diameter.annotations.DiameterAvpDefinition;
import com.mobius.software.telco.protocols.diameter.primitives.DiameterBitmask32;
/**
*
* @author yulian oifa
*
*/
/*
6.4.32 ROHC‑Result AVP
The ROHC‑Result AVP (AVP code 3530) is of type Unsigned32 and it shall contain a bit mask with values as defined table 6.4.32-1. Several bits indicating errors may be set in combination.
Table 6.4.32-1: ROHC‑Result AVP
Bit Name
Description
0 Success
The requested ROHC activation was successful.
1 Trying
The requested ROHC activation is still ongoing, The final result will be reported separately.
2 Authorization rejected
The requested ROHC activation failed because the BM‑SC did not authorize it.
3 Resources exceeded
The requested ROHC activation or execution failed because the BM‑SC could not provide sufficient resources.
4 Unknown Profile
The requested ROHC activation failed because the BM‑SC does not support the requested ROHC profile.
5 System error
The requested ROHC activation or execution failed due to some internal system error in the BM-SC.
6 No Traffic
The ROHC execution was terminated because the BM-SC did not detect any user plane traffic for a longer period.
*/
@DiameterAvpDefinition(code = TgppAvpCodes.ROHC_RESULT, vendorId = VendorIDs.TGPP_ID, must = false, name = "ROHC‑Result")
public interface ROHCResult extends DiameterBitmask32
{
public static final int SUCCESS_BIT = 0;
public static final int TRYING_BIT = 1;
public static final int AUTHORIZATION_REJECTED_BIT = 2;
public static final int RESOURCED_EXCEEDED_BIT = 3;
public static final int UNKNOWN_PROFILE_BIT = 4;
public static final int SYSTEM_ERROR_BIT = 5;
public static final int NO_TRAFFIC_BIT = 6;
public void setSuccessBit(boolean isOn);
public boolean isSuccessBitSet();
public void setTryingBit(boolean isOn);
public boolean isTryingBitSet();
public void setAuthorizationRejectBit(boolean isOn);
public boolean isAuthorizationRejectBitSet();
public void setResourcesExceededBit(boolean isOn);
public boolean isResourcesExceededBitSet();
public void setUnknownProfileBit(boolean isOn);
public boolean isUnknownProfileBitSet();
public void setSystemErrorBit(boolean isOn);
public boolean isSystemErrorBitSet();
public void setNoTrafficBit(boolean isOn);
public boolean isNoTrafficBitSet();
}