cim14.smallcase1.case1_EQ.xml Maven / Gradle / Ivy
Go to download
Show more of this group Show more artifacts with this name
Show all versions of powsybl-cgmes-model-test Show documentation
Show all versions of powsybl-cgmes-model-test Show documentation
CGMES network model for testing
<?xml version="1.0" encoding="UTF-8"?> <rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:cim="http://iec.ch/TC57/2009/CIM-schema-cim14#"> <cim:OperationalLimitType rdf:ID="_AC_PATL_OLT"> <cim:OperationalLimitType.direction rdf:resource="http://iec.ch/TC57/2009/CIM-schema-cim14#OperationalLimitDirectionKind.absoluteValue"/> <cim:OperationalLimitType.acceptableDuration>45000</cim:OperationalLimitType.acceptableDuration> <cim:IdentifiedObject.name>PATL</cim:IdentifiedObject.name> </cim:OperationalLimitType> <cim:BaseVoltage rdf:ID="_BV_0"> <cim:BaseVoltage.isDC>false</cim:BaseVoltage.isDC> <cim:BaseVoltage.nominalVoltage>21</cim:BaseVoltage.nominalVoltage> <cim:IdentifiedObject.name>0</cim:IdentifiedObject.name> </cim:BaseVoltage> <cim:BaseVoltage rdf:ID="_BV_1"> <cim:BaseVoltage.isDC>false</cim:BaseVoltage.isDC> <cim:BaseVoltage.nominalVoltage>380</cim:BaseVoltage.nominalVoltage> <cim:IdentifiedObject.name>1</cim:IdentifiedObject.name> </cim:BaseVoltage> <cim:BaseVoltage rdf:ID="_BV_2"> <cim:BaseVoltage.isDC>false</cim:BaseVoltage.isDC> <cim:BaseVoltage.nominalVoltage>380</cim:BaseVoltage.nominalVoltage> <cim:IdentifiedObject.name>2</cim:IdentifiedObject.name> </cim:BaseVoltage> <cim:ControlArea rdf:ID="_CA_1"> <cim:ControlArea.netInterchange>0</cim:ControlArea.netInterchange> <cim:ControlArea.pTolerance>0</cim:ControlArea.pTolerance> <cim:IdentifiedObject.name>_CA_1</cim:IdentifiedObject.name> </cim:ControlArea> <cim:PowerTransformer rdf:ID="_GEN_____-GRID____-1_PT"> <cim:Equipment.MemberOf_EquipmentContainer rdf:resource="#_GEN______SS"/> <cim:IdentifiedObject.name>GEN -GRID -1</cim:IdentifiedObject.name> </cim:PowerTransformer> <cim:TransformerWinding rdf:ID="_GEN_____-GRID____-1_TW_EX"> <cim:TransformerWinding.windingType rdf:resource="http://iec.ch/TC57/2009/CIM-schema-cim14#WindingType.secondary"/> <cim:TransformerWinding.connectionType rdf:resource="http://iec.ch/TC57/2009/CIM-schema-cim14#WindingConnection.Y"/> <cim:TransformerWinding.g>0</cim:TransformerWinding.g> <cim:TransformerWinding.b>0</cim:TransformerWinding.b> <cim:TransformerWinding.MemberOf_PowerTransformer rdf:resource="#_GEN_____-GRID____-1_PT"/> <cim:TransformerWinding.r>0</cim:TransformerWinding.r> <cim:TransformerWinding.ratedS>500</cim:TransformerWinding.ratedS> <cim:TransformerWinding.ratedU>419</cim:TransformerWinding.ratedU> <cim:TransformerWinding.x>0</cim:TransformerWinding.x> <cim:ConductingEquipment.BaseVoltage rdf:resource="#_BV_1"/> </cim:TransformerWinding> <cim:CurrentLimit rdf:ID="_GEN_____-GRID____-1_TW_EX_CL"> <cim:CurrentLimit.value>759.671</cim:CurrentLimit.value> <cim:OperationalLimit.OperationalLimitSet rdf:resource="#_GEN_____-GRID____-1_TW_EX_OLS"/> <cim:OperationalLimit.OperationalLimitType rdf:resource="#_TW_PATL_OLT"/> <cim:IdentifiedObject.name>GEN -GRID -1_TW_EX_CL</cim:IdentifiedObject.name> </cim:CurrentLimit> <cim:OperationalLimitSet rdf:ID="_GEN_____-GRID____-1_TW_EX_OLS"> <cim:OperationalLimitSet.Terminal rdf:resource="#_GEN_____-GRID____-1_TW_EX_TE"/> <cim:IdentifiedObject.name>GEN -GRID -1_TW_EX_OLS</cim:IdentifiedObject.name> </cim:OperationalLimitSet> <cim:Terminal rdf:ID="_GEN_____-GRID____-1_TW_EX_TE"> <cim:Terminal.sequenceNumber>2</cim:Terminal.sequenceNumber> <cim:Terminal.ConductingEquipment rdf:resource="#_GEN_____-GRID____-1_TW_EX"/> <cim:IdentifiedObject.name>GEN -GRID -1_TW_EX_TE</cim:IdentifiedObject.name> </cim:Terminal> <cim:TransformerWinding rdf:ID="_GEN_____-GRID____-1_TW_OR"> <cim:TransformerWinding.windingType rdf:resource="http://iec.ch/TC57/2009/CIM-schema-cim14#WindingType.primary"/> <cim:TransformerWinding.connectionType rdf:resource="http://iec.ch/TC57/2009/CIM-schema-cim14#WindingConnection.Y"/> <cim:TransformerWinding.g>0</cim:TransformerWinding.g> <cim:TransformerWinding.b>-0</cim:TransformerWinding.b> <cim:TransformerWinding.MemberOf_PowerTransformer rdf:resource="#_GEN_____-GRID____-1_PT"/> <cim:TransformerWinding.r>0.001323</cim:TransformerWinding.r> <cim:TransformerWinding.ratedS>500</cim:TransformerWinding.ratedS> <cim:TransformerWinding.ratedU>21</cim:TransformerWinding.ratedU> <cim:TransformerWinding.x>0.141114</cim:TransformerWinding.x> <cim:ConductingEquipment.BaseVoltage rdf:resource="#_BV_0"/> </cim:TransformerWinding> <cim:CurrentLimit rdf:ID="_GEN_____-GRID____-1_TW_OR_CL"> <cim:CurrentLimit.value>13746.4</cim:CurrentLimit.value> <cim:OperationalLimit.OperationalLimitSet rdf:resource="#_GEN_____-GRID____-1_TW_OR_OLS"/> <cim:OperationalLimit.OperationalLimitType rdf:resource="#_TW_PATL_OLT"/> <cim:IdentifiedObject.name>GEN -GRID -1_TW_OR_CL</cim:IdentifiedObject.name> </cim:CurrentLimit> <cim:OperationalLimitSet rdf:ID="_GEN_____-GRID____-1_TW_OR_OLS"> <cim:OperationalLimitSet.Terminal rdf:resource="#_GEN_____-GRID____-1_TW_OR_TE"/> <cim:IdentifiedObject.name>GEN -GRID -1_TW_OR_OLS</cim:IdentifiedObject.name> </cim:OperationalLimitSet> <cim:Terminal rdf:ID="_GEN_____-GRID____-1_TW_OR_TE"> <cim:Terminal.sequenceNumber>1</cim:Terminal.sequenceNumber> <cim:Terminal.ConductingEquipment rdf:resource="#_GEN_____-GRID____-1_TW_OR"/> <cim:IdentifiedObject.name>GEN -GRID -1_TW_OR_TE</cim:IdentifiedObject.name> </cim:Terminal> <cim:GeneratingUnit rdf:ID="_GEN______GU"> <cim:GeneratingUnit.nominalP>0</cim:GeneratingUnit.nominalP> <cim:GeneratingUnit.minOperatingP>-999</cim:GeneratingUnit.minOperatingP> <cim:GeneratingUnit.maxOperatingP>999</cim:GeneratingUnit.maxOperatingP> <cim:Equipment.MemberOf_EquipmentContainer rdf:resource="#_GEN______VL"/> <cim:IdentifiedObject.name>GEN </cim:IdentifiedObject.name> </cim:GeneratingUnit> <cim:SynchronousMachine rdf:ID="_GEN______SM"> <cim:SynchronousMachine.ratedS>0</cim:SynchronousMachine.ratedS> <cim:SynchronousMachine.minQ>-999</cim:SynchronousMachine.minQ> <cim:SynchronousMachine.r>0</cim:SynchronousMachine.r> <cim:SynchronousMachine.qPercent>1</cim:SynchronousMachine.qPercent> <cim:SynchronousMachine.MemberOf_GeneratingUnit rdf:resource="#_GEN______GU"/> <cim:SynchronousMachine.operatingMode rdf:resource="http://iec.ch/TC57/2009/CIM-schema-cim14#SynchronousMachineOperatingMode.generator"/> <cim:SynchronousMachine.x>0</cim:SynchronousMachine.x> <cim:SynchronousMachine.type rdf:resource="http://iec.ch/TC57/2009/CIM-schema-cim14#SynchronousMachineType.generator"/> <cim:SynchronousMachine.maxQ>999</cim:SynchronousMachine.maxQ> <cim:RegulatingCondEq.RegulatingControl rdf:resource="#_GEN______SM_RC"/> <cim:Equipment.MemberOf_EquipmentContainer rdf:resource="#_GEN______VL"/> <cim:IdentifiedObject.name>GEN </cim:IdentifiedObject.name> </cim:SynchronousMachine> <cim:RegulatingControl rdf:ID="_GEN______SM_RC"> <cim:RegulatingControl.discrete>false</cim:RegulatingControl.discrete> <cim:RegulatingControl.targetRange>0</cim:RegulatingControl.targetRange> <cim:RegulatingControl.mode rdf:resource="http://iec.ch/TC57/2009/CIM-schema-cim14#RegulatingControlModeKind.voltage"/> <cim:RegulatingControl.targetValue>21</cim:RegulatingControl.targetValue> <cim:RegulatingControl.Terminal rdf:resource="#_GEN______SM_TE"/> </cim:RegulatingControl> <cim:Terminal rdf:ID="_GEN______SM_TE"> <cim:Terminal.sequenceNumber>1</cim:Terminal.sequenceNumber> <cim:Terminal.ConductingEquipment rdf:resource="#_GEN______SM"/> <cim:IdentifiedObject.name>GEN </cim:IdentifiedObject.name> </cim:Terminal> <cim:Substation rdf:ID="_GEN______SS"> <cim:Substation.Region rdf:resource="#_SGR_1_"/> <cim:IdentifiedObject.name>GEN _SS</cim:IdentifiedObject.name> </cim:Substation> <cim:VoltageLevel rdf:ID="_GEN______VL"> <cim:VoltageLevel.BaseVoltage rdf:resource="#_BV_0"/> <cim:VoltageLevel.MemberOf_Substation rdf:resource="#_GEN______SS"/> <cim:IdentifiedObject.name>GEN _VL</cim:IdentifiedObject.name> </cim:VoltageLevel> <cim:ACLineSegment rdf:ID="_GRID____-INF_____-1_AC"> <cim:Conductor.gch>0</cim:Conductor.gch> <cim:Conductor.x>86.64</cim:Conductor.x> <cim:Conductor.bch>0</cim:Conductor.bch> <cim:Conductor.r>0</cim:Conductor.r> <cim:ConductingEquipment.BaseVoltage rdf:resource="#_BV_2"/> <cim:IdentifiedObject.name>GRID -INF -1</cim:IdentifiedObject.name> </cim:ACLineSegment> <cim:CurrentLimit rdf:ID="_GRID____-INF_____-1_AC_CL"> <cim:CurrentLimit.value>9116.06</cim:CurrentLimit.value> <cim:OperationalLimit.OperationalLimitSet rdf:resource="#_GRID____-INF_____-1_AC_OLS"/> <cim:OperationalLimit.OperationalLimitType rdf:resource="#_AC_PATL_OLT"/> <cim:IdentifiedObject.name>GRID -INF -1_AC_CL</cim:IdentifiedObject.name> </cim:CurrentLimit> <cim:OperationalLimitSet rdf:ID="_GRID____-INF_____-1_AC_OLS"> <cim:OperationalLimitSet.Terminal rdf:resource="#_GRID____-INF_____-1_AC_TE_OR"/> <cim:IdentifiedObject.name>GRID -INF -1_AC_OLS</cim:IdentifiedObject.name> </cim:OperationalLimitSet> <cim:Terminal rdf:ID="_GRID____-INF_____-1_AC_TE_EX"> <cim:Terminal.sequenceNumber>2</cim:Terminal.sequenceNumber> <cim:Terminal.ConductingEquipment rdf:resource="#_GRID____-INF_____-1_AC"/> <cim:IdentifiedObject.name>GRID -INF -1_AC_TE_EX</cim:IdentifiedObject.name> </cim:Terminal> <cim:Terminal rdf:ID="_GRID____-INF_____-1_AC_TE_OR"> <cim:Terminal.sequenceNumber>1</cim:Terminal.sequenceNumber> <cim:Terminal.ConductingEquipment rdf:resource="#_GRID____-INF_____-1_AC"/> <cim:IdentifiedObject.name>GRID -INF -1_AC_TE_OR</cim:IdentifiedObject.name> </cim:Terminal> <cim:VoltageLevel rdf:ID="_GRID_____VL"> <cim:VoltageLevel.BaseVoltage rdf:resource="#_BV_1"/> <cim:VoltageLevel.MemberOf_Substation rdf:resource="#_GEN______SS"/> <cim:IdentifiedObject.name>GRID _VL</cim:IdentifiedObject.name> </cim:VoltageLevel> <cim:GeographicalRegion rdf:ID="_GR_1_"> <cim:IdentifiedObject.name>1 </cim:IdentifiedObject.name> </cim:GeographicalRegion> <cim:GeneratingUnit rdf:ID="_INF______GU"> <cim:GeneratingUnit.nominalP>0</cim:GeneratingUnit.nominalP> <cim:GeneratingUnit.minOperatingP>-999999</cim:GeneratingUnit.minOperatingP> <cim:GeneratingUnit.maxOperatingP>999999</cim:GeneratingUnit.maxOperatingP> <cim:Equipment.MemberOf_EquipmentContainer rdf:resource="#_INF______VL"/> <cim:IdentifiedObject.name>INF </cim:IdentifiedObject.name> </cim:GeneratingUnit> <cim:SynchronousMachine rdf:ID="_INF______SM"> <cim:SynchronousMachine.ratedS>0</cim:SynchronousMachine.ratedS> <cim:SynchronousMachine.minQ>-999999</cim:SynchronousMachine.minQ> <cim:SynchronousMachine.r>0</cim:SynchronousMachine.r> <cim:SynchronousMachine.qPercent>1</cim:SynchronousMachine.qPercent> <cim:SynchronousMachine.MemberOf_GeneratingUnit rdf:resource="#_INF______GU"/> <cim:SynchronousMachine.operatingMode rdf:resource="http://iec.ch/TC57/2009/CIM-schema-cim14#SynchronousMachineOperatingMode.generator"/> <cim:SynchronousMachine.x>0</cim:SynchronousMachine.x> <cim:SynchronousMachine.type rdf:resource="http://iec.ch/TC57/2009/CIM-schema-cim14#SynchronousMachineType.generator"/> <cim:SynchronousMachine.maxQ>999999</cim:SynchronousMachine.maxQ> <cim:RegulatingCondEq.RegulatingControl rdf:resource="#_INF______SM_RC"/> <cim:Equipment.MemberOf_EquipmentContainer rdf:resource="#_INF______VL"/> <cim:IdentifiedObject.name>INF </cim:IdentifiedObject.name> </cim:SynchronousMachine> <cim:RegulatingControl rdf:ID="_INF______SM_RC"> <cim:RegulatingControl.discrete>false</cim:RegulatingControl.discrete> <cim:RegulatingControl.targetRange>0</cim:RegulatingControl.targetRange> <cim:RegulatingControl.mode rdf:resource="http://iec.ch/TC57/2009/CIM-schema-cim14#RegulatingControlModeKind.voltage"/> <cim:RegulatingControl.targetValue>419</cim:RegulatingControl.targetValue> <cim:RegulatingControl.Terminal rdf:resource="#_INF______SM_TE"/> </cim:RegulatingControl> <cim:Terminal rdf:ID="_INF______SM_TE"> <cim:Terminal.sequenceNumber>1</cim:Terminal.sequenceNumber> <cim:Terminal.ConductingEquipment rdf:resource="#_INF______SM"/> <cim:IdentifiedObject.name>INF </cim:IdentifiedObject.name> </cim:Terminal> <cim:Substation rdf:ID="_INF______SS"> <cim:Substation.Region rdf:resource="#_SGR_1_"/> <cim:IdentifiedObject.name>INF _SS</cim:IdentifiedObject.name> </cim:Substation> <cim:VoltageLevel rdf:ID="_INF______VL"> <cim:VoltageLevel.BaseVoltage rdf:resource="#_BV_2"/> <cim:VoltageLevel.MemberOf_Substation rdf:resource="#_INF______SS"/> <cim:IdentifiedObject.name>INF _VL</cim:IdentifiedObject.name> </cim:VoltageLevel> <cim:SubGeographicalRegion rdf:ID="_SGR_1_"> <cim:SubGeographicalRegion.Region rdf:resource="#_GR_1_"/> <cim:IdentifiedObject.name>1 </cim:IdentifiedObject.name> </cim:SubGeographicalRegion> <cim:OperationalLimitType rdf:ID="_T3_PATL_OLT"> <cim:OperationalLimitType.direction rdf:resource="http://iec.ch/TC57/2009/CIM-schema-cim14#OperationalLimitDirectionKind.absoluteValue"/> <cim:OperationalLimitType.acceptableDuration>45000</cim:OperationalLimitType.acceptableDuration> <cim:IdentifiedObject.name>PATL</cim:IdentifiedObject.name> </cim:OperationalLimitType> <cim:OperationalLimitType rdf:ID="_TW_PATL_OLT"> <cim:OperationalLimitType.direction rdf:resource="http://iec.ch/TC57/2009/CIM-schema-cim14#OperationalLimitDirectionKind.absoluteValue"/> <cim:OperationalLimitType.acceptableDuration>45000</cim:OperationalLimitType.acceptableDuration> <cim:IdentifiedObject.name>PATL</cim:IdentifiedObject.name> </cim:OperationalLimitType> <cim:IEC61970CIMVersion rdf:ID="version"> <cim:IEC61970CIMVersion.version>IEC61970CIM14v02</cim:IEC61970CIMVersion.version> <cim:IEC61970CIMVersion.date>2009-05-10</cim:IEC61970CIMVersion.date> </cim:IEC61970CIMVersion> </rdf:RDF>