com.intelligt.modbus.jlibmodbus.msg.ModbusResponseFactory Maven / Gradle / Ivy
package com.intelligt.modbus.jlibmodbus.msg;
import com.intelligt.modbus.jlibmodbus.msg.base.ModbusMessage;
import com.intelligt.modbus.jlibmodbus.msg.base.ModbusRequest;
import com.intelligt.modbus.jlibmodbus.msg.base.ModbusResponse;
import com.intelligt.modbus.jlibmodbus.msg.response.*;
import com.intelligt.modbus.jlibmodbus.utils.ModbusFunctionCode;
/*
* Copyright (C) 2016 "Invertor" Factory", JSC
* [http://www.sbp-invertor.ru]
*
* This file is part of JLibModbus.
*
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*
* Authors: Vladislav Y. Kochedykov, software engineer.
* email: [email protected]
*/
final public class ModbusResponseFactory implements ModbusMessageFactory {
private ModbusResponseFactory() {
}
static public ModbusResponseFactory getInstance() {
return SingletonHolder.instance;
}
/**
* This method creates a #ModbusResponse instance from #functionCode
*
* @param functionCode a number representing a modbus function
* @return an instance of a specific ModbusRequest
* @see ModbusRequest
* @see ModbusMessageFactory
* @see ModbusResponseFactory
*/
@Override
public ModbusMessage createMessage(int functionCode) {
ModbusResponse msg;
switch (ModbusFunctionCode.get(functionCode)) {
case READ_COILS:
msg = new ReadCoilsResponse();
break;
case READ_DISCRETE_INPUTS:
msg = new ReadDiscreteInputsResponse();
break;
case READ_HOLDING_REGISTERS:
msg = new ReadHoldingRegistersResponse();
break;
case READ_INPUT_REGISTERS:
msg = new ReadInputRegistersResponse();
break;
case WRITE_SINGLE_COIL:
msg = new WriteSingleCoilResponse();
break;
case WRITE_SINGLE_REGISTER:
msg = new WriteSingleRegisterResponse();
break;
case WRITE_MULTIPLE_COILS:
msg = new WriteMultipleCoilsResponse();
break;
case WRITE_MULTIPLE_REGISTERS:
msg = new WriteMultipleRegistersResponse();
break;
case MASK_WRITE_REGISTER:
msg = new MaskWriteRegisterResponse();
break;
case READ_WRITE_MULTIPLE_REGISTERS:
msg = new ReadWriteMultipleRegistersResponse();
break;
case READ_FIFO_QUEUE:
msg = new ReadFifoQueueResponse();
break;
case READ_FILE_RECORD:
msg = new ReadFileRecordResponse();
break;
case WRITE_FILE_RECORD:
msg = new WriteFileRecordResponse();
break;
case READ_EXCEPTION_STATUS:
msg = new ReadExceptionStatusResponse();
break;
case REPORT_SLAVE_ID:
msg = new ReportSlaveIdResponse();
break;
case GET_COMM_EVENT_COUNTER:
msg = new GetCommEventCounterResponse();
break;
case GET_COMM_EVENT_LOG:
msg = new GetCommEventLogResponse();
break;
case DIAGNOSTICS:
msg = new DiagnosticsResponse();
break;
case ENCAPSULATED_INTERFACE_TRANSPORT:
msg = new EncapsulatedInterfaceTransportResponse();
break;
default:
msg = new IllegalFunctionResponse(functionCode);
}
if (ModbusFunctionCode.isException(functionCode)) {
msg.setException();
}
return msg;
}
static private class SingletonHolder {
final static private ModbusResponseFactory instance = new ModbusResponseFactory();
}
}
© 2015 - 2026 Weber Informatics LLC | Privacy Policy