package com.zepben.evolve.cim.iec61970.base.wires
import com.zepben.evolve.cim.iec61970.base.core.PhaseCode
import com.zepben.evolve.cim.iec61970.base.core.PowerSystemResource
import com.zepben.evolve.cim.iec61970.base.core.Terminal
import com.zepben.evolve.services.common.extensions.asUnmodifiable
import com.zepben.evolve.services.common.extensions.getByMRID
import com.zepben.evolve.services.common.extensions.validateReference
/**
* Specifies a set of equipment that works together to control a power system quantity such as voltage or flow.
* Remote bus voltage control is possible by specifying the controlled terminal located at some place remote from the controlling equipment.
* The specified terminal shall be associated with the connectivity node of the controlled point. The most specific subtype of RegulatingControl shall be used
* in case such equipment participate in the control, e.g. TapChangerControl for tap changers.
*
* For flow control, load sign convention is used, i.e. positive sign means flow out from a TopologicalNode (bus) into the conducting equipment.
*
* The attribute minAllowedTargetValue and maxAllowedTargetValue are required in the following cases:
* For a power generating module operated in power factor control mode to specify maximum and minimum power factor values;
* Whenever it is necessary to have an off center target voltage for the tap changer regulator. For instance, due to long cables to offshore wind farms and the
* need to have a simpler setup at the offshore transformer platform, the voltage is controlled from the land at the connection point for the offshore wind
* farm.
*
* Since there usually is a voltage rise along the cable, there is typically an overvoltage of up 3-4 kV compared to the on shore station.
* Thus, in normal operation the tap changer on the on shore station is operated with a target set point, which is in the lower parts of the dead band.
*
* The attributes minAllowedTargetValue and maxAllowedTargetValue are not related to the attribute targetDeadband, and thus they are not treated as an
* alternative of the targetDeadband. They are needed due to limitations in the local substation controller.
*
* The attribute targetDeadband is used to prevent the power flow from move the tap position in circles (hunting) that is to be used regardless of the
* attributes minAllowedTargetValue and maxAllowedTargetValue.
*
* @property discrete The regulation is performed in a discrete mode. This applies to equipment with discrete controls, e.g. tap changers and shunt compensators.
* @property mode The regulating control mode presently available. This specification allows for determining the kind of regulation without need for obtaining
* the units from a schedule.
* @property monitoredPhase Phase voltage controlling this regulator, measured at regulator location.
* @property targetDeadband This is a deadband used with discrete control to avoid excessive update of controls like tap changers and shunt compensator banks
* while regulating. The units are the base units appropriate for the mode. The attribute shall be a positive value or zero. If [RegulatingControl.discrete] is
* set to "false", the RegulatingControl.targetDeadband is to be ignored. Note that for instance, if the targetValue is 100 kV and the targetDeadband is 2 kV
* the range is from 99 to 101 kV.
* @property targetValue The target value specified for case input. This value can be used for the target value without the use of schedules. The value has the
* units appropriate to the mode attribute.
* @property enabled The flag tells if regulation is enabled.
* @property maxAllowedTargetValue Maximum allowed target value (RegulatingControl.targetValue).
* @property minAllowedTargetValue Minimum allowed target value (RegulatingControl.targetValue).
* @property ratedCurrent The rated current of associated CT in amps for this RegulatingControl. Forms the base used to convert Line Drop Compensation settings
* from ohms to voltage.
* @property terminal The terminal associated with this regulating control. The terminal is associated instead of a node, since the terminal could connect into
* either a topological node or a connectivity node. Sometimes it is useful to model regulation at a terminal of a bus bar object.
* @property regulatingCondEqs The [RegulatingCondEq] that are controlled by this regulating control scheme.
*/
abstract class RegulatingControl(mRID: String = "") : PowerSystemResource(mRID) {
var discrete: Boolean? = null
var mode: RegulatingControlModeKind = RegulatingControlModeKind.UNKNOWN_CONTROL_MODE
var monitoredPhase: PhaseCode = PhaseCode.NONE
var targetDeadband: Float? = null
var targetValue: Double? = null
var enabled: Boolean? = null
var maxAllowedTargetValue: Double? = null
var minAllowedTargetValue: Double? = null
var ratedCurrent: Double? = null
var terminal: Terminal? = null
private var _regulatingCondEqs: MutableList? = null
val regulatingCondEqs: List get() = _regulatingCondEqs.asUnmodifiable()
/**
* Get the number of entries in the [RegulatingCondEq] collection.
*/
fun numRegulatingCondEqs(): Int = _regulatingCondEqs?.size ?: 0
/**
* [RegulatingCondEq]'s controlled by this [RegulatingControl].
*
* @param mRID the mRID of the required [RegulatingCondEq]
* @return The [RegulatingCondEq] with the specified [mRID] if it exists, otherwise null
*/
fun getRegulatingCondEq(mRID: String): RegulatingCondEq? = _regulatingCondEqs.getByMRID(mRID)
/**
* @param regulatingCondEq the regulating conducting equipment controlled by this [RegulatingControl].
* @return true if the regulating conducting equipment is associated.
* @return A reference to this [RegulatingControl] to allow fluent use.
*/
fun addRegulatingCondEq(regulatingCondEq: RegulatingCondEq): RegulatingControl {
if (validateReference(regulatingCondEq, ::getRegulatingCondEq, "A RegulatingCondEq"))
return this
_regulatingCondEqs = _regulatingCondEqs ?: mutableListOf()
_regulatingCondEqs!!.add(regulatingCondEq)
return this
}
/**
* @param regulatingCondEq the regulating conducting equipment to disassociate from this [RegulatingControl].
* @return this [RegulatingControl]
*/
fun removeRegulatingCondEq(regulatingCondEq: RegulatingCondEq): Boolean {
val ret = _regulatingCondEqs?.remove(regulatingCondEq) == true
if (_regulatingCondEqs.isNullOrEmpty()) _regulatingCondEqs = null
return ret
}
/**
* Clear this [RegulatingControl]'s associated [RegulatingCondEq]'s
* @return this [RegulatingControl]
*/
fun clearRegulatingCondEqs(): RegulatingControl {
_regulatingCondEqs = null
return this
}
}