com.zepben.evolve.cim.iec61970.infiec61970.protection.ProtectionKind.kt Maven / Gradle / Ivy
Go to download
Show more of this group Show more artifacts with this name
Show all versions of evolve-sdk Show documentation
Show all versions of evolve-sdk Show documentation
SDK for interaction with the evolve platform
/*
* Copyright 2022 Zeppelin Bend Pty Ltd
*
* This Source Code Form is subject to the terms of the Mozilla Public
* License, v. 2.0. If a copy of the MPL was not distributed with this
* file, You can obtain one at https://mozilla.org/MPL/2.0/.
*/
package com.zepben.evolve.cim.iec61970.infiec61970.protection
/**
* The kind of protection being provided by this protection equipment.
*
* @property UNKNOWN Unknown
* @property JG Overcurrent
* @property JGG Instantaneous
* @property JGGG Instantaneous
* @property JT Thermal overload
* @property J0 Ground overcurrent
* @property J0GG Instantaneous ground overcurrent
* @property SEF Sensitive earth fault
* @property VG Overvoltage
* @property VGG Instantaneous overvoltage
* @property VL Undervoltage
* @property VLL Instantaneous
* @property V0G Zero-sequence overvoltage
* @property V0GG Instantaneous zero-sequence overvoltage
* @property JDIFF Differential Current
* @property FREQ Under frequency
* @property FREQG Over frequency
* @property ZL Phase distance
* @property Z0L Ground distance
* @property LE Load encroachment
* @property J2G Negative-sequence overcurrent
* @property MULTI_FUNCTION A multifunctional relay for universal usages
* @property GROUND_CURRENT A device used to monitor and protect electrical equipment from damage caused by ground faults
* @property GROUND_VOLTAGE A device used to detect contact accidents between an electric path and ground caused by arc ground faults
* @property NETWORK_PROTECTOR Is a special self-contained air breaker or switching unit having a full complement of current, potential and control transformers, as well as relay functionality.
* @property DISTANCE A device used to detect faults on long-distance lines, pinpointing not only the fault condition but also measuring the distance between the current sensing mechanism and the fault location in the wire.
* @property NEGATIVE_OVERCURRENT A device used to protect generators from the unbalanced load by detecting negative sequence current.
* @property POWER A device that uses an electromagnet to open or close a circuit when the input (coil) is correctly excited
* @property SECTIONALIZER A device that automatically isolates a faulted section of line from the rest of the distribution system
* @property AUTO_TRANSFORMER A device used to regulate the voltage of transmission lines and can also be used to transform voltages.
*/
enum class ProtectionKind {
UNKNOWN,
JG,
JGG,
JGGG,
JT,
J0,
J0GG,
SEF,
VG,
VGG,
VL,
VLL,
V0G,
V0GG,
JDIFF,
FREQ,
FREQG,
ZL,
Z0L,
LE,
J2G,
MULTI_FUNCTION,
GROUND_CURRENT,
GROUND_VOLTAGE,
NETWORK_PROTECTOR,
DISTANCE,
NEGATIVE_OVERCURRENT,
POWER,
SECTIONALIZER,
AUTO_TRANSFORMER
}