package com.zepben.evolve.cim.iec61970.base.equivalents
/**
* The class represents equivalent branches. In cases where a transformer phase shift is modelled and the EquivalentBranch
* is spanning the same nodes, the impedance quantities for the EquivalentBranch shall consider the needed phase shift.
*
* @property negativeR12 Negative sequence series resistance from terminal sequence 1 to terminal sequence 2. Used for short circuit data exchange according
* to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange.
* @property negativeR21 Negative sequence series resistance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according
* to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange.
* @property negativeX12 Negative sequence series reactance from terminal sequence 1 to terminal sequence 2. Used for short circuit data exchange according
* to IEC 60909. Usage : EquivalentBranch is a result of network reduction prior to the data exchange.
* @property negativeX21 Negative sequence series reactance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according
* to IEC 60909. Usage: EquivalentBranch is a result of network reduction prior to the data exchange.
* @property positiveR12 Positive sequence series resistance from terminal sequence 1 to terminal sequence 2 . Used for short circuit data exchange according
* to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange.
* @property positiveR21 Positive sequence series resistance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according
* to IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange.
* @property positiveX12 Positive sequence series reactance from terminal sequence 1 to terminal sequence 2. Used for short circuit data exchange according
* to IEC 60909. Usage : EquivalentBranch is a result of network reduction prior to the data exchange.
* @property positiveX21 Positive sequence series reactance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according
* to IEC 60909. Usage : EquivalentBranch is a result of network reduction prior to the data exchange.
* @property r Positive sequence series resistance of the reduced branch.
* @property r21 Resistance from terminal sequence 2 to terminal sequence 1 .Used for steady state power flow. This attribute is optional and represent
* unbalanced network such as off-nominal phase shifter. If only EquivalentBranch.r is given, then EquivalentBranch.r21 is assumed equal
* to EquivalentBranch.r. Usage rule : EquivalentBranch is a result of network reduction prior to the data exchange.
* @property x Positive sequence series reactance of the reduced branch.
* @property x21 Reactance from terminal sequence 2 to terminal sequence 1. Used for steady state power flow. This attribute is optional and represents
* an unbalanced network such as off-nominal phase shifter. If only EquivalentBranch.x is given, then EquivalentBranch.x21 is assumed
* equal to EquivalentBranch.x. Usage rule: EquivalentBranch is a result of network reduction prior to the data exchange.
* @property zeroR12 Zero sequence series resistance from terminal sequence 1 to terminal sequence 2. Used for short circuit data exchange according to
* IEC 60909. EquivalentBranch is a result of network reduction prior to the data exchange.
* @property zeroR21 Zero sequence series resistance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according to
* IEC 60909. Usage : EquivalentBranch is a result of network reduction prior to the data exchange.
* @property zeroX12 Zero sequence series reactance from terminal sequence 1 to terminal sequence 2. Used for short circuit data exchange according to
* IEC 60909. Usage : EquivalentBranch is a result of network reduction prior to the data exchange.
* @property zeroX21 Zero sequence series reactance from terminal sequence 2 to terminal sequence 1. Used for short circuit data exchange according to
* IEC 60909. Usage : EquivalentBranch is a result of network reduction prior to the data exchange.
*/
class EquivalentBranch @JvmOverloads constructor(mRID: String = "") : EquivalentEquipment(mRID) {
var negativeR12: Double? = null
var negativeR21: Double? = null
var negativeX12: Double? = null
var negativeX21: Double? = null
var positiveR12: Double? = null
var positiveR21: Double? = null
var positiveX12: Double? = null
var positiveX21: Double? = null
var r: Double? = null
var r21: Double? = null
var x: Double? = null
var x21: Double? = null
var zeroR12: Double? = null
var zeroR21: Double? = null
var zeroX12: Double? = null
var zeroX21: Double? = null
}