All Downloads are FREE. Search and download functionalities are using the official Maven repository.

src.com.ibm.as400.access.JobLog Maven / Gradle / Ivy

The newest version!
///////////////////////////////////////////////////////////////////////////////
//
// JTOpen (IBM Toolbox for Java - OSS version)
//
// Filename:  JobLog.java
//
// The source code contained herein is licensed under the IBM Public License
// Version 1.0, which has been approved by the Open Source Initiative.
// Copyright (C) 1997-2007 International Business Machines Corporation and
// others.  All rights reserved.
//
///////////////////////////////////////////////////////////////////////////////

package com.ibm.as400.access;

import java.beans.PropertyChangeListener;
import java.beans.PropertyChangeSupport;
import java.beans.PropertyVetoException;
import java.beans.VetoableChangeListener;
import java.beans.VetoableChangeSupport;
import java.io.IOException;
import java.io.Serializable;
import java.util.Enumeration;
import java.util.Vector;
/**
 Represents a job log on the system.  This class is used to get a list of messages in a job log or to write 
 messages to a job log.
 

QueuedMessage objects have many attributes. Only some of these attribute values are set, depending on how a QueuedMessage object is created. The following is a list of attributes whose values can be set on QueuedMessage objects returned in a list of job log messages:

  • 0101 Alert option
  • 0201 Replacement data or impromptu message text
  • 0301 Message
  • 0302 Message with replacement data
  • 0401 Message help
  • 0402 Message help with replacement data
  • 0403 Message help with formatting characters
  • 0404 Message help with replacement data and formatting characters
  • 0501 Default reply
  • 0602 Sender type
  • 0603 Sending program name
  • 0604 Sending module name
  • 0605 Sending procedure name
  • 0606 Number of sending statement numbers
  • 0607 Sending user profile
  • 0702 Receiving type
  • 0703 Receiving program name
  • 0704 Receiving module name
  • 0705 Receiving procedure name
  • 0706 Number of receiving statement numbers
  • 0801 Message file library used
  • 1001 Reply status
  • 1101 Request status
  • 1201 Request level
  • 1301 Coded character set identifier (CCSID) for text
  • 1302 CCSID conversion status indicator for text
  • 1303 Coded character set identifier (CCSID) for data
  • 1304 CCSID conversion status indicator for data
@see com.ibm.as400.access.QueuedMessage **/ public class JobLog implements Serializable { static final long serialVersionUID = 4L; // We don't currently allow the user to specify a direction or any other attributes, so we just hardcode these. private static final int maxMessageLength_ = 511; private static final int maxMessageHelpLength_ = 3000; // Header size for the api qgygtle 80 bytes for Message Selection // Information and 1 byte for the message queue name private static final int qgygtleHeaderLength_ = 81; // The system where the job log is located. private AS400 system_; // The job name. private String name_ = "*"; // The job user name. private String user_ = ""; // The job number. private String number_ = ""; // Length of the job log message list. private int length_; // Handle that references the user space used by the open list APIs. private byte[] handle_; // If the list info has changed, close the old handle before loading the new one. private boolean closeHandle_ = false; // The direction of the list. private boolean listDirection_ = true; // The starting message key. private byte[] startingMessageKey_; // The list of field identifiers that are received private Vector numberOfFieldIdentifiers_ = new Vector(); // Valid Field Identifiers. Default identifiers are 101, 302, 404, 603, 501, and 1001. // The default identifiers are set in the load() method. //DEFAULT VALUE public static final int ALERT_OPTION = 101; public static final int REPLACEMENT_DATA = 201; public static final int MESSAGE = 301; //DEFAULT VALUE public static final int MESSAGE_WITH_REPLACEMENT_DATA = 302; public static final int MESSAGE_HELP = 401; public static final int MESSAGE_HELP_WITH_REPLACEMENT_DATA = 402; public static final int MESSAGE_HELP_WITH_FORMATTING_CHARACTERS = 403; //DEFAULT VALUE public static final int MESSAGE_HELP_WITH_REPLACEMENT_DATA_AND_FORMATTING_CHARACTERS = 404; //DEFAULT VALUE public static final int DEFAULT_REPLY = 501; public static final int SENDER_TYPE = 602; //DEFAULT VALUE public static final int SENDING_PROGRAM_NAME = 603; public static final int SENDING_MODULE_NAME = 604; public static final int SENDING_PROCEDURE_NAME = 605; public static final int SENDING_STATEMENT_NUMBERS= 606; public static final int SENDING_USER_PROFILE = 607; public static final int RECEIVING_TYPE = 702; public static final int RECEIVING_PROGRAM_NAME = 703; public static final int RECEIVING_MODULE_NAME = 704; public static final int RECEIVING_PROCEDURE_NAME = 705; public static final int RECEIVING_STATEMENT_NUMBERS = 706; public static final int MESSAGE_FILE_LIBRARY_USED = 801; //DEFAULT VALUE public static final int REPLY_STATUS = 1001; public static final int REQUEST_STATUS = 1101; public static final int REQUEST_LEVEL = 1201; public static final int CCSID_FOR_TEXT = 1301; public static final int CCSID_CONVERSION_STATUS_TEXT = 1302; public static final int CCSID_FOR_DATA = 1303; public static final int CCSID_CONVERSION_STATUS_DATA = 1304; // List of property change event bean listeners. private transient PropertyChangeSupport propertyChangeListeners_ = null; // Set on first add. // List of vetoable change event bean listeners. private transient VetoableChangeSupport vetoableChangeListeners_ = null; // Set on first add. /** Constructs a JobLog object. The system must be provided later. The job information defaults to the server job in which the program is run. **/ public JobLog() { super(); if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Adding default list information: REPLY_STATUS, SENDING_PROGRAM_NAME, DEFAULT_REPLY, MESSAGE_HELP_WITH_REPLACEMENT_DATA_AND_FORMATTING_CHARACTERS, MESSAGE_WITH_REPLACEMENT_DATA, ALERT_OPTION "); // Add the default list information addDefaultListInformation(); if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Constructing JobLog object."); } /** Constructs a JobLog object. The job information defaults to the server job in which the program is run. @param system The system object representing the system on which the job log exists. **/ public JobLog(AS400 system) { super(); if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Constructing JobLog object, system: " + system); if (system == null) { Trace.log(Trace.ERROR, "Parameter 'system' is null."); throw new NullPointerException("system"); } if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Adding default list information: REPLY_STATUS, SENDING_PROGRAM_NAME, DEFAULT_REPLY, MESSAGE_HELP_WITH_REPLACEMENT_DATA_AND_FORMATTING_CHARACTERS, MESSAGE_WITH_REPLACEMENT_DATA, ALERT_OPTION "); // Add the default list information addDefaultListInformation(); system_ = system; } /** Constructs a JobLog object. @param system The system object representing the system on which the job log exists. @param name The job name. @param user The job user name. @param number The job number. **/ public JobLog(AS400 system, String name, String user, String number) { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Constructing JobLog object, system: " + system + ", name: " + name + ", user: " + user + ", number: " + number); if (system == null) { Trace.log(Trace.ERROR, "Parameter 'system' is null."); throw new NullPointerException("system"); } if (name == null) { Trace.log(Trace.ERROR, "Parameter 'name' is null."); throw new NullPointerException("name"); } if (user == null) { Trace.log(Trace.ERROR, "Parameter 'user' is null."); throw new NullPointerException("user"); } if (number == null) { Trace.log(Trace.ERROR, "Parameter 'number' is null."); throw new NullPointerException("number"); } if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Adding default list information: REPLY_STATUS, SENDING_PROGRAM_NAME, DEFAULT_REPLY, MESSAGE_HELP_WITH_REPLACEMENT_DATA_AND_FORMATTING_CHARACTERS, MESSAGE_WITH_REPLACEMENT_DATA, ALERT_OPTION "); // Add the default list information addDefaultListInformation(); system_ = system; name_ = name; user_ = user; number_ = number; } /** Adds a message attribute that will be retrieved for each joblog. This method allows the Joblog objects that are retrieved from this Joblog list to have some of their message attributes chosen by the caller.

The list of message attributes is maintained internally even when this JobList is closed and re-used. To start over with a new set of job attributes to retrieve, call {@link #clearAttributesToRetrieve clearAttributesToRetrieve()}. This will set all attributes to null including the default attributes. @param attribute The message attribute to retrieve. Possible values are all joblog attributes in the api document for the Open List of Job Log Messages (QGYOLJBL) API. * @throws IOException If an error occurs while communicating with the system. **/ public void addAttributeToRetrieve(int attribute) throws IOException { if( !numberOfFieldIdentifiers_.contains(new Integer(attribute)) ) { switch (attribute) { case 1001: //REPLY_STATUS: numberOfFieldIdentifiers_.add( new Integer(REPLY_STATUS)); break; case 603: //SENDING_PROGRAM_NAME: numberOfFieldIdentifiers_.add( new Integer(SENDING_PROGRAM_NAME)); break; case 501: //DEFAULT_REPLY: numberOfFieldIdentifiers_.add( new Integer(DEFAULT_REPLY)); break; case 404: //MESSAGE_HELP_WITH_REPLACEMENT_DATA_AND_FORMATTING_CHARACTERS: numberOfFieldIdentifiers_.add( new Integer(MESSAGE_HELP_WITH_REPLACEMENT_DATA_AND_FORMATTING_CHARACTERS)); break; case 302: //MESSAGE_WITH_REPLACEMENT_DATA: numberOfFieldIdentifiers_.add( new Integer(MESSAGE_WITH_REPLACEMENT_DATA)); break; case 101: //ALERT_OPTION: numberOfFieldIdentifiers_.add( new Integer(ALERT_OPTION)); break; case 201: //REPLACEMENT_DATA: numberOfFieldIdentifiers_.add( new Integer(REPLACEMENT_DATA)); break; case 301: //MESSAGE: numberOfFieldIdentifiers_.add( new Integer(MESSAGE)); break; case 401: //MESSAGE_HELP: numberOfFieldIdentifiers_.add( new Integer (MESSAGE_HELP)); break; case 402: //MESSAGE_HELP_WITH_REPLACEMENT_DATA: numberOfFieldIdentifiers_.add( new Integer(MESSAGE_HELP_WITH_REPLACEMENT_DATA)); break; case 403: //MESSAGE_HELP_WITH_FORMATTING_CHARACTERS: numberOfFieldIdentifiers_.add( new Integer(MESSAGE_HELP_WITH_FORMATTING_CHARACTERS)); break; case 602: //SENDER_TYPE: numberOfFieldIdentifiers_.add( new Integer(SENDER_TYPE)); break; case 604: //SENDING_MODULE_NAME: numberOfFieldIdentifiers_.add( new Integer(SENDING_MODULE_NAME)); break; case 605: //SENDING_PROCEDURE_NAME: numberOfFieldIdentifiers_.add( new Integer(SENDING_PROCEDURE_NAME)); break; case 606: //SENDING_STATEMENT_NUMBERS: numberOfFieldIdentifiers_.add( new Integer(SENDING_STATEMENT_NUMBERS)); break; case 607: //SENDING_USER_PROFILE: numberOfFieldIdentifiers_.add( new Integer(SENDING_USER_PROFILE)); break; case 702: //RECEIVING_TYPE: numberOfFieldIdentifiers_.add( new Integer(RECEIVING_TYPE)); break; case 703: //RECEIVING_PROGRAM_NAME: numberOfFieldIdentifiers_.add( new Integer(RECEIVING_PROGRAM_NAME)); break; case 704: //RECEIVING_MODULE_NAME: numberOfFieldIdentifiers_.add( new Integer(RECEIVING_MODULE_NAME)); break; case 705: //RECEIVING_PROCEDURE_NAME: numberOfFieldIdentifiers_.add( new Integer(RECEIVING_PROCEDURE_NAME)); break; case 706: //RECEIVING_STATEMENT_NUMBERS: numberOfFieldIdentifiers_.add( new Integer(RECEIVING_STATEMENT_NUMBERS)); break; case 801: //MESSAGE_FILE_LIBRARY_USED: numberOfFieldIdentifiers_.add( new Integer(MESSAGE_FILE_LIBRARY_USED)); break; case 1101: //REQUEST_STATUS: numberOfFieldIdentifiers_.add( new Integer(REQUEST_STATUS)); break; case 1201: //REQUEST_LEVEL: numberOfFieldIdentifiers_.add( new Integer(REQUEST_LEVEL)); break; case 1301: //CCSID_FOR_TEXT: numberOfFieldIdentifiers_.add( new Integer(CCSID_FOR_TEXT)); break; case 1302: //CCSID_CONVERSION_STATUS_TEXT: numberOfFieldIdentifiers_.add( new Integer(CCSID_CONVERSION_STATUS_TEXT)); break; case 1303: //CCSID_FOR_DATA: numberOfFieldIdentifiers_.add( new Integer(CCSID_FOR_DATA)); break; case 1304: //CCSID_CONVERSION_STATUS_DATA: numberOfFieldIdentifiers_.add( new Integer(CCSID_CONVERSION_STATUS_DATA)); break; default: Trace.log(Trace.ERROR, "Value of parameter 'attribute' is not valid: " + attribute); throw new ExtendedIllegalArgumentException("attribute", ExtendedIllegalArgumentException.PARAMETER_VALUE_NOT_VALID); } } } /** Clears the message attributes to be retrieved for a given Joblog. This removes all of the joblog attributes that would be retrieved including the default message attributes. If all message attributes are cleared a call to addAttributeToRetrieve must be called or an exception will be thrown. @see #addAttributeToRetrieve **/ public void clearAttributesToRetrieve() { numberOfFieldIdentifiers_.clear(); } /** Adds a PropertyChangeListener. The specified PropertyChangeListener's propertyChange() method will be called each time the value of any bound property is changed. @param listener The listener. @see #removePropertyChangeListener **/ public void addPropertyChangeListener(PropertyChangeListener listener) { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Adding property change listener."); if (listener == null) { Trace.log(Trace.ERROR, "Parameter 'listener' is null."); throw new NullPointerException("listener"); } synchronized (this) { // If first add. if (propertyChangeListeners_ == null) { propertyChangeListeners_ = new PropertyChangeSupport(this); } propertyChangeListeners_.addPropertyChangeListener(listener); } } /** Adds a VetoableChangeListener. The specified VetoableChangeListener's vetoableChange() method will be called each time the value of any constrained property is changed. @param listener The listener. @see #removeVetoableChangeListener **/ public void addVetoableChangeListener(VetoableChangeListener listener) { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Adding vetoable change listener."); if (listener == null) { Trace.log(Trace.ERROR, "Parameter 'listener' is null."); throw new NullPointerException("listener"); } synchronized (this) { // If first add. if (vetoableChangeListeners_ == null) { vetoableChangeListeners_ = new VetoableChangeSupport(this); } vetoableChangeListeners_.addVetoableChangeListener(listener); } } /** Closes the message list on the system. This releases any system resources previously in use by this message list. This will not close the connection to the Host Server job held by the associated AS400 object. @exception AS400SecurityException If a security or authority error occurs. @exception ErrorCompletingRequestException If an error occurs before the request is completed. @exception InterruptedException If this thread is interrupted. @exception IOException If an error occurs while communicating with the system. @exception ObjectDoesNotExistException If the object does not exist on the system. **/ public synchronized void close() throws AS400SecurityException, ErrorCompletingRequestException, InterruptedException, IOException, ObjectDoesNotExistException { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Closing job log message list, handle: ", handle_); if (handle_ == null) return; try { ListUtilities.closeList(system_, handle_); } finally { handle_ = null; closeHandle_ = false; } } /** Returns the number of messages in the job log. This method implicitly calls {@link #load load()}. @return The number of messages, or 0 if no list was retrieved. @see #load **/ public int getLength() { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Getting job log list length."); try { if (handle_ == null || closeHandle_) load(); } catch (Exception e) { Trace.log(Trace.ERROR, "Exception caught getting length of job log list:", e); if (e instanceof ExtendedIllegalStateException) throw (ExtendedIllegalStateException)e; } if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Length:", length_); return length_; } /** Returns the list direction. @return true if the messages will be sorted oldest to newest; false if they will be sorted newest to oldest. The default is true. **/ public boolean getListDirection() { return listDirection_; } /** Returns the list of messages in the job log. @return An Enumeration of QueuedMessage objects. @exception AS400SecurityException If a security or authority error occurs. @exception ErrorCompletingRequestException If an error occurs before the request is completed. @exception InterruptedException If this thread is interrupted. @exception IOException If an error occurs while communicating with the system. @exception ObjectDoesNotExistException If the object does not exist on the system. **/ public Enumeration getMessages() throws AS400SecurityException, ErrorCompletingRequestException, InterruptedException, IOException, ObjectDoesNotExistException { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Retrieving job log message list."); // Need to get the length. if (handle_ == null || closeHandle_) load(); return new QueuedMessageEnumeration(this, length_); } /** Returns a subset of the list of messages in the job log. This method allows the user to retrieve the message list from the system in pieces. If a call to {@link #load load()} is made (either implicitly or explicitly), then the messages at a given list offset will change, so a subsequent call to getMessages() with the same listOffset and number will most likely not return the same QueuedMessages as the previous call. @param listOffset The offset in the list of messages (0-based). This value must be greater than or equal to 0 and less than the list length; or specify -1 to retrieve all of the messages. Note: Prior to JTOpen 7.2, this parameter was incorrectly described. @param number The number of messages to retrieve out of the list, starting at the specified listOffset. This value must be greater than or equal to 0 and less than or equal to the list length. If the listOffset is -1, this parameter is ignored. @return The array of retrieved {@link com.ibm.as400.access.QueuedMessage QueuedMessage} objects. The length of this array may not necessarily be equal to number, depending upon the size of the list on the system, and the specified listOffset. @exception AS400SecurityException If a security or authority error occurs. @exception ErrorCompletingRequestException If an error occurs before the request is completed. @exception InterruptedException If this thread is interrupted. @exception IOException If an error occurs while communicating with the system. @exception ObjectDoesNotExistException If the object does not exist on the system. @see com.ibm.as400.access.QueuedMessage **/ public QueuedMessage[] getMessages(int listOffset, int number) throws AS400SecurityException, ErrorCompletingRequestException, InterruptedException, IOException, ObjectDoesNotExistException { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Retrieving job log message list, list offset: " + listOffset + ", number:", number); if (listOffset < -1) { throw new ExtendedIllegalArgumentException("listOffset (" + listOffset + ")", ExtendedIllegalArgumentException.RANGE_NOT_VALID); } if (number < 0 && listOffset != -1) { throw new ExtendedIllegalArgumentException("number (" + number + ")", ExtendedIllegalArgumentException.RANGE_NOT_VALID); } if (handle_ == null || closeHandle_) load(); // this sets the length_ variable if (length_ == 0 || (number == 0 && listOffset != -1)) { return new QueuedMessage[0]; } if (listOffset == -1) { number = length_; // request entire list listOffset = 0; // ... starting at beginning of list } else if (listOffset >= length_) { if (Trace.traceOn_) Trace.log(Trace.WARNING, "Value of parameter 'listOffset' is beyond end of list:", listOffset + " (list length: " + length_ + ")"); return new QueuedMessage[0]; } else if (listOffset + number > length_) { number = length_ - listOffset; } int lengthOfReceiverVariable = 1024 * number; // Retrieve the entries in the list that was built by the most recent load(). byte[] data = ListUtilities.retrieveListEntries(system_, handle_, lengthOfReceiverVariable, number, listOffset, null); Converter conv = new Converter(system_.getCcsid(), system_); QueuedMessage[] messages = new QueuedMessage[number]; int offset = 0; for (int i = 0; i < messages.length; ++i) // each message { int entryOffset = BinaryConverter.byteArrayToInt(data, offset); int fieldOffset = BinaryConverter.byteArrayToInt(data, offset + 4); int numFields = BinaryConverter.byteArrayToInt(data, offset + 8); int messageSeverity = BinaryConverter.byteArrayToInt(data, offset + 12); String messageIdentifier = conv.byteArrayToString(data, offset + 16, 7).trim(); int messageType = (data[offset + 23] & 0x0F) * 10 + (data[offset + 24] & 0x0F); if (messageType == 0) messageType = -1; byte[] messageKey = new byte[4]; System.arraycopy(data, offset + 25, messageKey, 0, 4); String messageFileName = conv.byteArrayToString(data, offset + 29, 10).trim(); String messageFileLibrarySpecified = conv.byteArrayToString(data, offset + 39, 10).trim(); String dateSent = conv.byteArrayToString(data, offset + 49, 7); // CYYMMDD String timeSent = conv.byteArrayToString(data, offset + 56, 6); // HHMMSS messages[i] = new QueuedMessage(system_, messageSeverity, messageIdentifier, messageType, messageKey, messageFileName, messageFileLibrarySpecified, dateSent, timeSent); for (int j = 0; j < numFields; ++j) { int offsetToNextField = BinaryConverter.byteArrayToInt(data, fieldOffset); int fieldID = BinaryConverter.byteArrayToInt(data, fieldOffset + 8); byte type = data[fieldOffset + 12]; int dataLen = BinaryConverter.byteArrayToInt(data, fieldOffset + 28); if (type == (byte)0xC3) // 'C' { if ( fieldID == 201 ) { byte[] substitutionData = new byte[dataLen]; System.arraycopy(data, fieldOffset +32, substitutionData, 0, dataLen); messages[i].setValueInternal(fieldID, substitutionData); } else { messages[i].setValueInternal(fieldID, conv.byteArrayToString(data, fieldOffset + 32, dataLen)); } } else if (type == (byte)0xC2) // 'B' { if (dataLen > 4) { messages[i].setAsLong(fieldID, BinaryConverter.byteArrayToLong(data, fieldOffset + 32)); } else { messages[i].setAsInt(fieldID, BinaryConverter.byteArrayToInt(data, fieldOffset + 32)); } } else { int numStatements = BinaryConverter.byteArrayToInt(data, fieldOffset + 32); String[] statements = new String[numStatements]; for (int k = 0; k < numStatements; ++k) { statements[k] = conv.byteArrayToString(data, fieldOffset + 36 + (k * 10), 10); } messages[i].setValueInternal(fieldID, statements); } fieldOffset = offsetToNextField; } offset = entryOffset; } return messages; } /** Returns the job name. @return The job name, or "*" if none has been set. @see #setName **/ public String getName() { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Getting name: " + name_); return name_; } /** Returns the job number. @return The job number, or "" if none has been set. @see #setNumber **/ public String getNumber() { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Getting number: " + number_); return number_; } /** Returns the starting message key. @return The key. @see #setStartingMessageKey **/ public byte[] getStartingMessageKey() { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Getting starting message key:", startingMessageKey_); return startingMessageKey_; } /** Returns the system object representing the system on which the job log exists. @return The system object representing the system on which the job log exists. If the system has not been set, null is returned. @see #setSystem **/ public AS400 getSystem() { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Getting system: " + system_); return system_; } /** Returns the job user name. @return The job user name, or "" if none has been set. @see #setUser **/ public String getUser() { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Getting user: " + user_); return user_; } /** Loads the list of messages on the system. This method informs the system to build a list of messages. This method blocks until the system returns the total number of messages it has compiled. A subsequent call to {@link #getMessages getMessages()} will retrieve the actual message information and attributes for each message in the list from the system.

This method updates the list length. @exception AS400SecurityException If a security or authority error occurs. @exception ErrorCompletingRequestException If an error occurs before the request is completed. @exception InterruptedException If this thread is interrupted. @exception IOException If an error occurs while communicating with the system. @exception ObjectDoesNotExistException If the object does not exist on the system. @see #getLength **/ public synchronized void load() throws AS400SecurityException, ErrorCompletingRequestException, InterruptedException, IOException, ObjectDoesNotExistException { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Loading job log message list."); if (system_ == null) { Trace.log(Trace.ERROR, "Cannot connect to server before setting system."); throw new ExtendedIllegalStateException("system", ExtendedIllegalStateException.PROPERTY_NOT_SET); } if (!name_.equals("*")) { if (user_.equals("")) { Trace.log(Trace.ERROR, "Cannot connect to server before setting user."); throw new ExtendedIllegalStateException("user", ExtendedIllegalStateException.PROPERTY_NOT_SET); } if (number_.equals("")) { Trace.log(Trace.ERROR, "Cannot connect to server before setting number."); throw new ExtendedIllegalStateException("number", ExtendedIllegalStateException.PROPERTY_NOT_SET); } } // Close the previous list. if (closeHandle_) close(); // Create the message selection information. byte[] messageSelectionInformation = listInformationArray(); // Setup program parameters. ProgramParameter[] parameters = new ProgramParameter[] { // Receiver variable, output, char(*). new ProgramParameter(0), // Length of receiver variable, input, binary(4). new ProgramParameter(new byte[] { 0x00, 0x00, 0x00, 0x00 } ), // List information, output, char(80). new ProgramParameter(ListUtilities.LIST_INFO_LENGTH), // Number of records to return, input, binary(4). // Special value '-1' indicates that "all records are built synchronously in the list". new ProgramParameter(new byte[] { (byte)0xFF, (byte)0xFF, (byte)0xFF, (byte)0xFF } ), // Message selection information, input, char(*). new ProgramParameter(messageSelectionInformation), // Size of message selection information, input, binary(4). new ProgramParameter(BinaryConverter.intToByteArray(messageSelectionInformation.length)), // Error code, I/O, char(*). new ErrorCodeParameter(), }; // Call the program. This API is not thread safe. ProgramCall pc = new ProgramCall(system_, "/QSYS.LIB/QGY.LIB/QGYOLJBL.PGM", parameters); // not a threadsafe API if (!pc.run()) { throw new AS400Exception(pc.getMessageList()); } // List information returned. byte[] listInformation = parameters[2].getOutputData(); handle_ = new byte[4]; System.arraycopy(listInformation, 8, handle_, 0, 4); // Wait for the list-building to complete. listInformation = ListUtilities.waitForListToComplete(system_, handle_, listInformation); length_ = BinaryConverter.byteArrayToInt(listInformation, 0); if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Loaded job log message list, length: " + length_ + ", handle: ", handle_); } /** Removes the PropertyChangeListener. If the PropertyChangeListener is not on the list, nothing is done. @param listener The listener object. **/ public void removePropertyChangeListener(PropertyChangeListener listener) { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Removing property change listener."); if (listener == null) { Trace.log(Trace.ERROR, "Parameter 'listener' is null."); throw new NullPointerException("listener"); } // If we have listeners. if (propertyChangeListeners_ != null) { propertyChangeListeners_.removePropertyChangeListener(listener); } } /** Removes the VetoableChangeListener. If the VetoableChangeListener is not on the list, nothing is done. @param listener The listener object. **/ public void removeVetoableChangeListener(VetoableChangeListener listener) { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Removing vetoable change listener."); if (listener == null) { Trace.log(Trace.ERROR, "Parameter 'listener' is null."); throw new NullPointerException("listener"); } // If we have listeners. if (vetoableChangeListeners_ != null) { vetoableChangeListeners_.removeVetoableChangeListener(listener); } } /** Sets the list direction. @param listDirection true to sort the messages oldest to newest; false to sort them newest to oldest. The default is true. **/ public void setListDirection(boolean listDirection) { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Setting list direction: " + listDirection); synchronized (this) { listDirection_ = listDirection; if (handle_ != null) closeHandle_ = true; } } /** Sets the job name. This cannot be changed if the object has established a connection to the system. @param name The job name. @exception PropertyVetoException If any of the registered listeners vetos the property change. **/ public void setName(String name) throws PropertyVetoException { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Setting name: " + name); if (name == null) { Trace.log(Trace.ERROR, "Parameter 'name' is null."); throw new NullPointerException("name"); } if (propertyChangeListeners_ == null && vetoableChangeListeners_ == null) { synchronized (this) { name_ = name; if (handle_ != null) closeHandle_ = true; } } else { String oldValue = name_; String newValue = name; if (vetoableChangeListeners_ != null) { vetoableChangeListeners_.fireVetoableChange("name", oldValue, newValue); } synchronized (this) { name_ = name; if (handle_ != null) closeHandle_ = true; } if (propertyChangeListeners_ != null) { propertyChangeListeners_.firePropertyChange("name", oldValue, newValue); } } } /** Sets the job number. This cannot be changed if the object has established a connection to the system. @param number The job number. @exception PropertyVetoException If any of the registered listeners vetos the property change. **/ public void setNumber(String number) throws PropertyVetoException { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Setting number: " + number); if (number == null) { Trace.log(Trace.ERROR, "Parameter 'number' is null."); throw new NullPointerException("number"); } if (propertyChangeListeners_ == null && vetoableChangeListeners_ == null) { synchronized (this) { number_ = number; if (handle_ != null) closeHandle_ = true; } } else { String oldValue = number_; String newValue = number; if (vetoableChangeListeners_ != null) { vetoableChangeListeners_.fireVetoableChange("number", oldValue, newValue); } synchronized (this) { number_ = number; if (handle_ != null) closeHandle_ = true; } if (propertyChangeListeners_ != null) { propertyChangeListeners_.firePropertyChange("number", oldValue, newValue); } } } /** Sets the message key used to begin searching for messages to list from the corresponding entry in the job log. Any valid message key will work, including {@link com.ibm.as400.access.MessageQueue#OLDEST MessageQueue.OLDEST} and {@link com.ibm.as400.access.MessageQueue#NEWEST MessageQueue#NEWEST}. @param startingMessageKey The key. Specify null to set it back to the default, which will be OLDEST or NEWEST based on the list direction. **/ public void setStartingMessageKey(byte[] startingMessageKey) { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Setting starting message key:", startingMessageKey); synchronized (this) { startingMessageKey_ = startingMessageKey; if (handle_ != null) closeHandle_ = true; } } /** Sets the system. This cannot be changed if the object has established a connection to the system. @param system The system object representing the system on which the job log exists. @exception PropertyVetoException If any of the registered listeners vetos the property change. **/ public void setSystem(AS400 system) throws PropertyVetoException { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Setting system: " + system); if (system == null) { Trace.log(Trace.ERROR, "Parameter 'system' is null."); throw new NullPointerException("system"); } if (handle_ != null) { Trace.log(Trace.ERROR, "Cannot set property 'system' after connect."); throw new ExtendedIllegalStateException("system", ExtendedIllegalStateException.PROPERTY_NOT_CHANGED); } if (propertyChangeListeners_ == null && vetoableChangeListeners_ == null) { system_ = system; } else { AS400 oldValue = system_; AS400 newValue = system; if (vetoableChangeListeners_ != null) { vetoableChangeListeners_.fireVetoableChange("system", oldValue, newValue); } system_ = system; if (propertyChangeListeners_ != null) { propertyChangeListeners_.firePropertyChange("system", oldValue, newValue); } } } /** Sets the job user name. This cannot be changed if the object has established a connection to the system. @param user The job user name. @exception PropertyVetoException If any of the registered listeners vetos the property change. **/ public void setUser(String user) throws PropertyVetoException { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Setting user: " + user); if (user == null) { Trace.log(Trace.ERROR, "Parameter 'user' is null."); throw new NullPointerException("user"); } if (propertyChangeListeners_ == null && vetoableChangeListeners_ == null) { synchronized (this) { user_ = user; if (handle_ != null) closeHandle_ = true; } } else { String oldValue = user_; String newValue = user; if (vetoableChangeListeners_ != null) { vetoableChangeListeners_.fireVetoableChange("user", oldValue, newValue); } synchronized (this) { user_ = user; if (handle_ != null) closeHandle_ = true; } if (propertyChangeListeners_ != null) { propertyChangeListeners_.firePropertyChange("user", oldValue, newValue); } } } /** Writes a program message to the job log for the job in which the program is running.
Note: The program runs in the job of the Remote Command Host Server (QZRCSRVS) unless it is invoked "on-thread" on the system. @param system The system object representing the system on which the job log exists. If the system specifies localhost, the message is written to the job log of the process from which this method is called. Otherwise the message is written to the QZRCSRVS job. @param messageID The message ID. The message must be in the default message file /QSYS.LIB/QCPFMSG.MSGF. @param messageType The message type. Possible values are:

  • AS400Message.COMPLETION
  • AS400Message.DIAGNOSTIC
  • AS400Message.INFORMATIONAL
  • AS400Message.ESCAPE
The message type must be AS400Message.INFORMATIONAL for an immediate message. @see com.ibm.as400.access.ProgramCall#isStayOnThread() @exception AS400SecurityException If a security or authority error occurs. @exception ErrorCompletingRequestException If an error occurs before the request is completed. @exception InterruptedException If this thread is interrupted. @exception IOException If an error occurs while communicating with the system. @exception ObjectDoesNotExistException If the object does not exist on the system. **/ public static void writeMessage(AS400 system, String messageID, int messageType) throws AS400SecurityException, ErrorCompletingRequestException, InterruptedException, IOException, ObjectDoesNotExistException { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Writing message to job log, system: " + system + ", message ID: " + messageID + ", message type:", messageType); if (system == null) { Trace.log(Trace.ERROR, "Parameter 'system' is null."); throw new NullPointerException("system"); } if (messageID == null) { Trace.log(Trace.ERROR, "Parameter 'messageID' is null."); throw new NullPointerException("messageID"); } switch (messageType) { case AS400Message.COMPLETION: case AS400Message.DIAGNOSTIC: case AS400Message.INFORMATIONAL: case AS400Message.ESCAPE: break; default: Trace.log(Trace.ERROR, "Value of parameter 'messageType' is not valid: " + messageType); throw new ExtendedIllegalArgumentException("messageType (" + messageType + ")", ExtendedIllegalArgumentException.PARAMETER_VALUE_NOT_VALID); } sendProgramMessage(system, messageID, "/QSYS.LIB/QCPFMSG.MSGF", null, messageType, false); } /** Writes a program message to the job log for the job in which the program is running.
Note: The program runs in the job of the Remote Command Host Server (QZRCSRVS) unless it is invoked "on-thread" on the system. @param system The system. If the system specifies localhost, the message is written to the job log of the process from which this method is called. Otherwise the message is written to the QZRCSRVS job. @param messageID The message ID. The message must be in the default message file /QSYS.LIB/QCPFMSG.MSGF. @param messageType The message type. Possible values are:
  • AS400Message.COMPLETION
  • AS400Message.DIAGNOSTIC
  • AS400Message.INFORMATIONAL
  • AS400Message.ESCAPE
The message type must be AS400Message.INFORMATIONAL for an immediate message. @param substitutionData The substitution data. The substitution data can be from 0-32767 bytes for a conventional message and from 1-6000 bytes for an immediate message. @see com.ibm.as400.access.ProgramCall#isStayOnThread() @exception AS400SecurityException If a security or authority error occurs. @exception ErrorCompletingRequestException If an error occurs before the request is completed. @exception InterruptedException If this thread is interrupted. @exception IOException If an error occurs while communicating with the system. @exception ObjectDoesNotExistException If the object does not exist on the system. **/ public static void writeMessage(AS400 system, String messageID, int messageType, byte[] substitutionData) throws AS400SecurityException, ErrorCompletingRequestException, InterruptedException, IOException, ObjectDoesNotExistException { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Writing message to job log, system: " + system + ", message ID: " + messageID + ", message type: " + messageType + ", substitution data:", substitutionData); if (system == null) { Trace.log(Trace.ERROR, "Parameter 'system' is null."); throw new NullPointerException("system"); } if (messageID == null) { Trace.log(Trace.ERROR, "Parameter 'messageID' is null."); throw new NullPointerException("messageID"); } switch (messageType) { case AS400Message.COMPLETION: case AS400Message.DIAGNOSTIC: case AS400Message.INFORMATIONAL: case AS400Message.ESCAPE: break; default: Trace.log(Trace.ERROR, "Value of parameter 'messageType' is not valid: " + messageType); throw new ExtendedIllegalArgumentException("messageType (" + messageType + ")", ExtendedIllegalArgumentException.PARAMETER_VALUE_NOT_VALID); } sendProgramMessage(system, messageID, "/QSYS.LIB/QCPFMSG.MSGF", substitutionData, messageType, false); } /** Writes a program message to the job log for the job in which the program is running.
Note: The program runs in the job of the Remote Command Host Server (QZRCSRVS) unless it is invoked "on-thread" on the system. @param system The system. If the system specifies localhost, the message is written to the job log of the process from which this method is called. Otherwise the message is written to the QZRCSRVS job. @param messageID The message ID. @param messageType The message type. Possible values are:
  • AS400Message.COMPLETION
  • AS400Message.DIAGNOSTIC
  • AS400Message.INFORMATIONAL
  • AS400Message.ESCAPE
The message type must be AS400Message.INFORMATIONAL for an immediate message. @param messageFile The integrated file system path name of the message file. @see com.ibm.as400.access.ProgramCall#isStayOnThread() @exception AS400SecurityException If a security or authority error occurs. @exception ErrorCompletingRequestException If an error occurs before the request is completed. @exception InterruptedException If this thread is interrupted. @exception IOException If an error occurs while communicating with the system. @exception ObjectDoesNotExistException If the object does not exist on the system. **/ public static void writeMessage(AS400 system, String messageID, int messageType, String messageFile) throws AS400SecurityException, ErrorCompletingRequestException, InterruptedException, IOException, ObjectDoesNotExistException { if (system == null) { Trace.log(Trace.ERROR, "Parameter 'system' is null."); throw new NullPointerException("system"); } if (messageID == null) { Trace.log(Trace.ERROR, "Parameter 'messageID' is null."); throw new NullPointerException("messageID"); } switch (messageType) { case AS400Message.COMPLETION: case AS400Message.DIAGNOSTIC: case AS400Message.INFORMATIONAL: case AS400Message.ESCAPE: break; default: Trace.log(Trace.ERROR, "Value of parameter 'messageType' is not valid: " + messageType); throw new ExtendedIllegalArgumentException("messageType (" + messageType + ")", ExtendedIllegalArgumentException.PARAMETER_VALUE_NOT_VALID); } if (messageFile == null) { Trace.log(Trace.ERROR, "Parameter 'messageFile' is null."); throw new NullPointerException("messageFile"); } QSYSObjectPathName.validatePath(messageFile, "MSGF"); sendProgramMessage(system, messageID, messageFile, null, messageType, false); } /** Writes a program message to the job log for the job in which the program is running.
Note: The program runs in the job of the Remote Command Host Server (QZRCSRVS) unless it is invoked "on-thread" on the system. @param system The system. If the system specifies localhost, the message is written to the job log of the process from which this method is called. Otherwise the message is written to the QZRCSRVS job. @param messageID The message ID. @param messageType The message type. Possible values are:
  • AS400Message.COMPLETION
  • AS400Message.DIAGNOSTIC
  • AS400Message.INFORMATIONAL
  • AS400Message.ESCAPE
The message type must be AS400Message.INFORMATIONAL for an immediate message. @param messageFile The integrated file system path name of the message file. @param substitutionData The substitution data. The substitution data can be from 0-32767 bytes for a conventional message and from 1-6000 bytes for an immediate message. @see com.ibm.as400.access.ProgramCall#isStayOnThread() @exception AS400SecurityException If a security or authority error occurs. @exception ErrorCompletingRequestException If an error occurs before the request is completed. @exception InterruptedException If this thread is interrupted. @exception IOException If an error occurs while communicating with the system. @exception ObjectDoesNotExistException If the object does not exist on the system. **/ public static void writeMessage(AS400 system, String messageID, int messageType, String messageFile, byte[] substitutionData) throws AS400SecurityException, ErrorCompletingRequestException, InterruptedException, IOException, ObjectDoesNotExistException { if (system == null) { Trace.log(Trace.ERROR, "Parameter 'system' is null."); throw new NullPointerException("system"); } if (messageID == null) { Trace.log(Trace.ERROR, "Parameter 'messageID' is null."); throw new NullPointerException("messageID"); } switch (messageType) { case AS400Message.COMPLETION: case AS400Message.DIAGNOSTIC: case AS400Message.INFORMATIONAL: case AS400Message.ESCAPE: break; default: Trace.log(Trace.ERROR, "Value of parameter 'messageType' is not valid: " + messageType); throw new ExtendedIllegalArgumentException("messageType (" + messageType + ")", ExtendedIllegalArgumentException.PARAMETER_VALUE_NOT_VALID); } if (messageFile == null) { Trace.log(Trace.ERROR, "Parameter 'messageFile' is null."); throw new NullPointerException("messageFile"); } QSYSObjectPathName.validatePath(messageFile, "MSGF"); sendProgramMessage(system, messageID, messageFile, substitutionData, messageType, false); } /** Writes a program message to the job log for the job in which the program is running. The message is sent to the Remote Command Host Server (QZRCSRVS) unless true is specified for the onThread parameter and is invoked while running on the system. @param system The system. The system cannot be null. @param messageID The message ID. The message ID cannot be null. @param messageType The message type. Possible values are:
  • AS400Message.COMPLETION
  • AS400Message.DIAGNOSTIC
  • AS400Message.INFORMATIONAL
  • AS400Message.ESCAPE
The message type must be AS400Message.INFORMATIONAL for an immediate message. @param messageFile The integrated file system path name of the message file. If null is specified, the message file used is /QSYS.LIB/QCPFMSG.MSGF. @param substitutionData The substitution data. The substitution data can be from 0-32767 bytes for a conventional message and from 1-6000 bytes for an immediate message. If null is specified, no substitution data is used. @param onThread Whether or not to stay on thread when calling the API to write the message to the job log. true to write the message to the current job's job log, false to write the message to the Remote Command Host Server job's job log. Note that this parameter is meaningless unless this Java program is running on the system and the system object is using native optimizations. @see com.ibm.as400.access.ProgramCall#isStayOnThread() @exception AS400SecurityException If a security or authority error occurs. @exception ErrorCompletingRequestException If an error occurs before the request is completed. @exception InterruptedException If this thread is interrupted. @exception IOException If an error occurs while communicating with the system. @exception ObjectDoesNotExistException If the object does not exist on the system. **/ public static void writeMessage(AS400 system, String messageID, int messageType, String messageFile, byte[] substitutionData, boolean onThread) throws AS400SecurityException, ErrorCompletingRequestException, InterruptedException, IOException, ObjectDoesNotExistException { if (system == null) { Trace.log(Trace.ERROR, "Parameter 'system' is null."); throw new NullPointerException("system"); } if (messageID == null) { Trace.log(Trace.ERROR, "Parameter 'messageID' is null."); throw new NullPointerException("messageID"); } switch (messageType) { case AS400Message.COMPLETION: case AS400Message.DIAGNOSTIC: case AS400Message.INFORMATIONAL: case AS400Message.ESCAPE: break; default: Trace.log(Trace.ERROR, "Value of parameter 'messageType' is not valid: " + messageType); throw new ExtendedIllegalArgumentException("messageType (" + messageType + ")", ExtendedIllegalArgumentException.PARAMETER_VALUE_NOT_VALID); } if (messageFile == null) { Trace.log(Trace.ERROR, "Parameter 'messageFile' is null."); throw new NullPointerException("messageFile"); } QSYSObjectPathName.validatePath(messageFile, "MSGF"); sendProgramMessage(system, messageID, messageFile, substitutionData, messageType, onThread); } private static final byte[] typeCompletion_ = new byte[] { 0x5C, (byte)0xC3, (byte)0xD6, (byte)0xD4, (byte)0xD7, 0x40, 0x40, 0x40, 0x40, 0x40 }; // "*COMP " private static final byte[] typeDiagnostic_ = new byte[] { 0x5C, (byte)0xC4, (byte)0xC9, (byte)0xC1, (byte)0xC7, 0x40, 0x40, 0x40, 0x40, 0x40 }; // "*DIAG " private static final byte[] typeEscape_ = new byte[] { 0x5C, (byte)0xC5, (byte)0xE2, (byte)0xC3, (byte)0xC1, (byte)0xD7, (byte)0xC5, 0x40, 0x40, 0x40 }; // "*ESCAPE " private static final byte[] typeInformational_ = new byte[] { 0x5C, (byte)0xC9, (byte)0xD5, (byte)0xC6, (byte)0xD6, 0x40, 0x40, 0x40, 0x40, 0x40 }; // "*INFO " private static final byte[] callStackEntry_ = new byte[] { 0x5C, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40 }; // "* " private void addDefaultListInformation() { numberOfFieldIdentifiers_.add(new Integer(REPLY_STATUS)); numberOfFieldIdentifiers_.add(new Integer(SENDING_PROGRAM_NAME)); numberOfFieldIdentifiers_.add(new Integer(DEFAULT_REPLY)); numberOfFieldIdentifiers_.add(new Integer(MESSAGE_HELP_WITH_REPLACEMENT_DATA_AND_FORMATTING_CHARACTERS)); numberOfFieldIdentifiers_.add(new Integer(MESSAGE_WITH_REPLACEMENT_DATA)); numberOfFieldIdentifiers_.add(new Integer(ALERT_OPTION)); } private byte[] listInformationArray() throws IOException { byte [] messageSelectionInformation = new byte[ qgygtleHeaderLength_ + (numberOfFieldIdentifiers_.size() * 4) ]; // Generate text objects based on system CCSID. Converter conv = new Converter(system_.getCcsid(), system_); // List direction. The direction to list messages can be *NEXT or *PRV. if (listDirection_) System.arraycopy(new byte[] { 0x5C, (byte)0xD5, (byte)0xC5, (byte)0xE7, (byte)0xE3 }, 0, messageSelectionInformation, 0, 5); else System.arraycopy(new byte[] { 0x5C, (byte)0xD7, (byte)0xD9, (byte)0xE5, 0x40 }, 0, messageSelectionInformation, 0, 5); // Blank pad from end of List direction through Internal job identifier. for (int i = 5; i < 52; ++i) messageSelectionInformation[i] = 0x40; // Job name, user, and number conv.stringToByteArray(name_.toUpperCase().trim(), messageSelectionInformation, 10); conv.stringToByteArray(user_.toUpperCase().trim(), messageSelectionInformation, 20); conv.stringToByteArray(number_, messageSelectionInformation, 30); byte[] startingMessageKey = (startingMessageKey_ != null ? startingMessageKey_ : (listDirection_ ? MessageQueue.OLDEST : MessageQueue.NEWEST)); System.arraycopy(startingMessageKey, 0, messageSelectionInformation, 52, 4); // Only used for fields 401, 402, 403, or 404. BinaryConverter.intToByteArray(maxMessageLength_, messageSelectionInformation, 56); // Only used for fields 301 or 302. BinaryConverter.intToByteArray(maxMessageHelpLength_, messageSelectionInformation, 60); // Offset of identifiers. BinaryConverter.intToByteArray(80, messageSelectionInformation, 64); // Number of identifiers to return, which should be the amount of // objects in the vector numberOfFieldIdentifiers_ BinaryConverter.intToByteArray(numberOfFieldIdentifiers_.size(), messageSelectionInformation, 68); // Offset of call message queue name. The size of the header + number of // fields * 4 bytes - 1, which puts us at the end of the byte array - 1 BinaryConverter.intToByteArray((qgygtleHeaderLength_ + (numberOfFieldIdentifiers_.size() * 4) -1), messageSelectionInformation, 72); // Size of call message queue name. BinaryConverter.intToByteArray(1, messageSelectionInformation, 76); // Add the fields to the byte array Enumeration fields = numberOfFieldIdentifiers_.elements(); int offset = qgygtleHeaderLength_ - 1; while (fields.hasMoreElements()) { BinaryConverter.intToByteArray(((Integer)(fields.nextElement())).intValue(), messageSelectionInformation, offset); offset += 4; } // Call message queue name, EBCDIC '*', Messages from every call of the job are listed. messageSelectionInformation[ (qgygtleHeaderLength_ - 1 )+ (numberOfFieldIdentifiers_.size() * 4) ] = 0x5C; return messageSelectionInformation; } private static void sendProgramMessage(AS400 system, String messageID, String messageFile, byte[] replacementData, int messageType, boolean onThread) throws AS400SecurityException, ErrorCompletingRequestException, InterruptedException, IOException, ObjectDoesNotExistException { // Assume all parameters have been validated. Converter conv = new Converter(system.getCcsid(), system); byte[] messageIdentifier = new byte[] { 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40 }; conv.stringToByteArray(messageID, messageIdentifier, 0, 7); byte[] qualifiedMessageFileName = new byte[] { 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40, 0x40 }; QSYSObjectPathName path = new QSYSObjectPathName(messageFile); conv.stringToByteArray(path.getObjectName(), qualifiedMessageFileName, 0, 10); conv.stringToByteArray(path.getLibraryName(), qualifiedMessageFileName, 10, 10); if (replacementData == null) replacementData = new byte[0]; byte[] type = null; switch (messageType) { case AS400Message.COMPLETION: type = typeCompletion_; break; case AS400Message.DIAGNOSTIC: type = typeDiagnostic_; break; case AS400Message.ESCAPE: type = typeEscape_; break; case AS400Message.INFORMATIONAL: type = typeInformational_; break; default: break; } // Setup program parameters. ProgramParameter[] parameters = new ProgramParameter[] { // Message identifier, input, char(7). new ProgramParameter(messageIdentifier), // Qualified message file name, input, char(20). new ProgramParameter(qualifiedMessageFileName), // Message data or immediate text, input, char(*). new ProgramParameter(replacementData), // Length of message data or immediate text, input, binary(4). new ProgramParameter(BinaryConverter.intToByteArray(replacementData.length)), // Message type, input, char(10). new ProgramParameter(type), // Call stack entry, input, char(*). new ProgramParameter(callStackEntry_), // Call stack counter, input, binary(4). new ProgramParameter(new byte[] { 0x00, 0x00, 0x00, 0x00 } ), // Message key, output, char(4). new ProgramParameter(4), // Error code, I/O, char(*). new ErrorCodeParameter() }; ProgramCall pc = new ProgramCall(system, "/QSYS.LIB/QMHSNDPM.PGM", parameters); // The QMHSNDPM is threadsafe, but we want to stay on-thread // if (and only if) the user wants to write to the current job's log, // rather than to the remote command server's job log. if (onThread) pc.setThreadSafe(true); // force on-thread if (!pc.run()) { // If one message came back and it is the one we sent, // then we're OK. AS400Message[] msgs = pc.getMessageList(); if (msgs.length == 1 && msgs[0].getID().equals(messageID) && msgs[0].getType() == messageType) { if (Trace.traceOn_) Trace.log(Trace.INFORMATION, "The expected escape message is ignored."); return; } throw new AS400Exception(msgs); } } /** Closes the list on the system when this object is garbage collected. **/ protected void finalize() throws Throwable { if (Trace.traceOn_) Trace.log(Trace.DIAGNOSTIC, "Finalize method for job log invoked."); if (handle_ != null) try { close(); } catch (Throwable t) {} super.finalize(); } }




© 2015 - 2024 Weber Informatics LLC | Privacy Policy