bidib.BiDiBCV-13-124.xml Maven / Gradle / Ivy
<?xml version="1.0" encoding="UTF-8"?> <VendorCV xmlns="http://www.bidib.org/schema/vendorcv" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.bidib.org/schema/vendorcv /xsd/vendor_cv.xsd"> <Version Version="0.3" Lastupdate="20170219" Author="Gerhard Ehrne" Pid="124" Vendor="013" Description="S88-TLE-Interface"/> <CVDefinition> <Node> <Nodetext Lang="de-DE" Text="Allgemeine Einstellungen"/> <Nodetext Lang="en-EN" Text="Common settings"/> <CV Number="1" Type="Byte" Min="0" Max="255" Low="-" High="-" Values="-" Mode="ro"> <Description Lang="de-DE" Text="EE Version"/> <Description Lang="en-EN" Text="EE version"/> </CV> <CV Number="2" Type="Byte" Min="0" Max="255" Low="-" High="-" Values="-" Mode="ro"> <Description Lang="de-DE" Text="vendor_id"/> <Description Lang="en-EN" Text="vendor_id"/> </CV> <CV Number="3" Type="Int" Min="0" Max="255" Low="3" High="4" Values="-" Mode="ro"> <Description Lang="de-DE" Text="hw_serial_low"/> <Description Lang="en-EN" Text="hw_serial_low"/> </CV> <CV Number="4" Type="Int" Min="0" Max="255" Low="3" High="4" Values="-" Mode="ro"> <Description Lang="de-DE" Text="hw_serial_high"/> <Description Lang="en-EN" Text="hw_serial_high"/> </CV> <CV Number="5" Type="Byte" Min="0" Max="255" Low="-" High="-" Values="-" Mode="ro"> <Description Lang="de-DE" Text="main version"/> <Description Lang="en-EN" Text="main version"/> </CV> <CV Number="6" Type="Byte" Min="0" Max="255" Low="-" High="-" Values="-" Mode="ro"> <Description Lang="de-DE" Text="sub version"/> <Description Lang="en-EN" Text="sub version"/> </CV> <CV Number="7" Type="Byte" Min="0" Max="255" Low="-" High="-" Values="-" Mode="ro"> <Description Lang="de-DE" Text="compile run"/> <Description Lang="en-EN" Text="compile run"/> </CV> <CV Number="51" Type="Byte" Min="1" Max="16" Low="-" High="-" Values="-" Mode="ro"> <Description Lang="de-DE" Text="Anzahl der Melder (in Bytes). Wertebereich 1..16 entspricht 8..128 Melder. Nur gültig, falls alle Jumper offen. Wert über Feature setzen."/> <Description Lang="en-EN" Text="Number of detectors (in bytes). Range 1..16 equates to 8..128 detectors. Only valid if all jumpers are open. Set value thru feature."/> </CV> <CV Number="52" Type="Byte" Min="0" Max="255" Low="-" High="-" Values="-" Mode="rw"> <Description Lang="de-DE" Text="Timing, in Einheiten von 10us; Wertebereich 1..50, Default: 10. Angeben ist die Zeit Clock High und Clock Low."/> <Description Lang="en-EN" Text="Timing, in units of 10us. Value range 1..50, default: 10. Specified is the time of clock high and clock low."/> </CV> <CV Number="53" Type="Byte" Min="0" Max="2" Low="-" High="-" Values="-" Mode="rw"> <Description Lang="de-DE" Text="Offset für S88 Melder (in Bytes). Wertebereich 0..2 entspricht 0..16 Melder. Verschiebung der S88 Melder für TLE Melder."/> <Description Lang="en-EN" Text="Offset for S88 detectors (in bytes). Range 0..2 equates to 0..16 detectors. Moves the S88 detectors to get room for TLE detectors."/> </CV> <CV Number="61" Type="Byte" Min="10" Max="255" Low="-" High="-" Values="-" Mode="rw"> <Description Lang="de-DE" Text="Entprellzeit in Einheiten von 100us; Wertebereich 0..255, Default: 100. Angeben ist, wie lange das entprellen der Tasten und TLE dauert (100 = 10 ms)."/> <Description Lang="en-EN" Text="Debounce time, in units of 100us. Value range 0..255, default: 100. Specified is how long the debouncing of keys and TLE will occur (100 = 10ms)."/> </CV> <CV Number="62" Type="Byte" Min="0" Max="255" Low="-" High="-" Values="-" Mode="rw"> <Description Lang="de-DE" Text="Memory hold time, in Einheiten von 20ms; Wertebereich 0..255, Default: 0. Angeben ist, wie lange eine Belegung nach Freigabe aufrecht erhalten bleibt."/> <Description Lang="en-EN" Text="Memory hold time, in units of 20ms. Value range 0..255, default: 0. Specified is how long the occupancy will stay after release."/> </CV> </Node> </CVDefinition> </VendorCV>
© 2015 - 2025 Weber Informatics LLC | Privacy Policy