All Downloads are FREE. Search and download functionalities are using the official Maven repository.

bidib.BiDiBCV-13-105.xml Maven / Gradle / Ivy

The newest version!
<?xml version="1.0" encoding="UTF-8"?>
<VendorCV xmlns="http://www.bidib.org/schema/vendorcv" 
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" 
	xsi:schemaLocation="http://www.bidib.org/schema/vendorcv /xsd/vendor_cv.xsd">
    
    <Version Version="0.2" Lastupdate="20131021" Author="BiDiB-Mustermann" Pid="105" Vendor="013" Description="BiDiB-s88-Bridge"/>
    <CVDefinition>
        <Node>
            <Nodetext Lang="de-DE" Text="Allgemeine Einstellungen"/>
            <Nodetext Lang="en-EN" Text="Common settings"/>
            <CV Number="1" Type="Byte" Min="0" Max="255" Low="-" High="-" Values="-" Mode="ro">
                <Description Lang="de-DE" Text="vendor_id"/>
                <Description Lang="en-EN" Text="vendor_id"/>
            </CV>
            <CV Number="2" Type="Byte" Min="0" Max="255" Low="-" High="-" Values="-" Mode="ro">
                <Description Lang="de-DE" Text="hw_id"/>
                <Description Lang="en-EN" Text="hw_id"/>
            </CV>
            <CV Number="3" Type="Int" Min="0" Max="255" Low="3" High="4" Values="-" Mode="rw">
                <Description Lang="de-DE" Text="hw_serial_low"/>
                <Description Lang="en-EN" Text="hw_serial_low"/>
            </CV>
            <CV Number="4" Type="Int" Min="0" Max="255" Low="3" High="4" Values="-" Mode="rw">
                <Description Lang="de-DE" Text="hw_serial_high"/>
                <Description Lang="en-EN" Text="hw_serial_high"/>
            </CV>
            <CV Number="5" Type="Byte" Min="1" Max="16" Low="-" High="-" Values="-" Mode="rw">
                <Description Lang="de-DE" Text="Anzahl der Melder (in Bytes). Wertebereich 1..16 entspricht 8..128 Melder. Nur gültig, falls alle Jumper offen."/>
                <Description Lang="en-EN" Text="Number of detectors (in bytes). Range 1..16 equates to 8..128 detectors. Only valid if all jumpers are open."/>
            </CV>
            <CV Number="6" Type="Byte" Min="0" Max="255" Low="-" High="-" Values="-" Mode="rw">
                <Description Lang="de-DE" Text="Timing, in Einheiten von 10us; Wertebereich 1..50, Default: 10. Angeben ist die Zeit Clock High und Clock Low."/>
                <Description Lang="en-EN" Text="Timing, in units of 10us. Value range 1..50, default: 10. Specified is the time of clock high and clock low."/>
            </CV>
        </Node>
    </CVDefinition>
</VendorCV>