<?xml version="1.0" encoding="utf-8" ?>
<VendorCV xmlns="http://www.bidib.org/schema/vendorcv"
          xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
          xsi:schemaLocation="http://www.bidib.org/schema/vendorcv /xsd/vendor_cv.xsd">
		  <Version Version="2.00.02" Lastupdate="20160517" Author="Tillner, Andreas" Pid="204" Vendor="13" Description="BiDiBOne OneOC: 20x OC-Input">
	</Version>
	<Templates>
		<Template Name="About">
			<CV Number="0" Type="Byte" Min="0" Max="255" Low="-" High="-" Values="-" Mode="ro">
				<Description Lang="de-DE" Text="EEPROM Version"/>
			    <Description Lang="en-EN" Text="EEPROM Version"/>
			</CV>
			<CV Number="1" Type="Byte" Min="0" Max="255" Low="-" High="-" Values="-" Mode="ro">
				<Description Lang="de-DE" Text="Herstellerkennung"/>
			    <Description Lang="en-EN" Text="Vendor ID"/>
			</CV>
			<CV Number="2" Type="Int" Min="-" Max="-" Low="2" High="3" Values="-" Mode="ro">
				<Description Lang="de-DE" Text="Produktkennung (low)"/>
			    <Description Lang="en-EN" Text="ProductID (low)"/>
			</CV>
			<CV Number="3" Type="Int" Min="-" Max="-" Low="2" High="3" Values="-" Mode="ro">
				<Description Lang="de-DE" Text="Produktkennung (high)"/>
			    <Description Lang="en-EN" Text="ProductID (high)"/>
			</CV>
			<CV Number="4" Type="Byte" Min="0" Max="255" Low="-" High="-" Values="-" Mode="ro">
				<Description Lang="de-DE" Text="Firmware Version"/>
			    <Description Lang="en-EN" Text="Firmware main version"/>
			</CV>
			<CV Number="5" Type="Byte" Min="0" Max="255" Low="-" High="-" Values="-" Mode="ro">
				<Description Lang="de-DE" Text="Firmware Sub-Version"/>
			    <Description Lang="en-EN" Text="Firmware sub version"/>
			</CV>
			<CV Number="6" Type="Byte" Min="0" Max="255" Low="-" High="-" Values="-" Mode="ro">
				<Description Lang="de-DE" Text="Firmware Sub-Index"/>
			    <Description Lang="en-EN" Text="Firmware compile run"/>
			</CV>
		</Template>
		<Template Name="Sector">
			<CV Number="0" Type="Int" Min="0" Max="255" Low="0" High="1" Mode="rw" 	>
				<Description Lang="de-DE" Text="Länge der Messstrecke in mm (lowbyte)"/>
			    <Description Lang="en-EN" Text="Length of measuring track in mm (lowbyte))"/>
			</CV>
			<CV Number="1" Type="Int" Min="0" Max="255" Low="0" High="1" Mode="rw" >
				<Description Lang="de-DE" Text="Länge der Messstrecke in mm (highbyte)"/>
			    <Description Lang="en-EN" Text="Length of measuring track in mm (highbyte)"/>
			</CV>
			<CV Number="2" Type="Byte" Min="0" Max="19" Mode="rw" >
				<Description Lang="de-DE" Text="Startmelder der Messstrecke"/>
			    <Description Lang="en-EN" Text="Startdetector of the measuring track"/> 
			</CV>
			<CV Number="3" Type="Byte" Min="0" Max="19" Mode="rw" >
				<Description Lang="de-DE" Text="Endmelder der Messstrecke"/>
			    <Description Lang="en-EN" Text="Enddetector of the measuring track"/>
			</CV>
			<CV Number="4" Type="Bit" Radiobits="30" Mode="rw" >
			    <Description Lang="de-DE" Text="Messstrecke aktiviert" />
				<Description Lang="en-EN" Text="measuring track is aktive"/>
				<Bitdescription Bitnum="1" Lang="de-DE" Text="Messstrecke aktiv"/>
				<Bitdescription Bitnum="1" Lang="en-EN" Text="measuring track aktive"/>
				<Bitdescription Bitnum="2" Lang="de-DE" Help="Geschwindigkeitsmessung zwischen Start- u. Stopmelder." Text="Geschwindigkeitsmessung"/>
				<Bitdescription Bitnum="2" Lang="en-EN" Help="Speed measuring from start- to stopdetector." Text="Speed measuring"/>
				<Bitdescription Bitnum="3" Lang="de-DE" Help="Zeitmessung zwischen Start- u. Stopmelder." Text="Zeitmessung"/>
				<Bitdescription Bitnum="3" Lang="en-EN" Help="Time measuring from start- to stopdetector." Text="Time measuring"/>
				<Bitdescription Bitnum="4" Lang="de-DE" Help="Rundenzeit. Zeitmessung zwischen zwei Melungen des Startmelders." Text="Rundenzeit (Start- zu Startmelder)"/>
				<Bitdescription Bitnum="4" Lang="en-EN" Help="Time measuring between two triggers of the Startdetector." Text="Lap time (Start- to Startdetector)"/>
				<Bitdescription Bitnum="5" Lang="de-DE" Help="Rundenzähler. Zählt das Auslösen des Startmelders." Text="Rundenzähler (Startmelder)"/>
				<Bitdescription Bitnum="5" Lang="en-EN" Help="Lapcounter. Counts, how often the startdetector triggered." Text="Lapcounter (Startdetector)"/>
			</CV>
		</Template>
		<Template Name="OCC-Port">
			<Repeater Count="20" Next="1" Offset="0">
				<CV Number="130" Type="Bit" Min="-"  Max="-"  Low="-" High="-" Mode="rw" Values="1">
					<Description Lang="de-DE" Text="Port %%d"/>
					<Description Lang="en-EN" Text="Port %%d"/>
					<Bitdescription Bitnum="1" Lang="de-DE" Text="OCC high = 1 oder low = 0"/>
					<Bitdescription Bitnum="1" Lang="en-EN" Text="OCC high = 1 or low = 1"/>
				</CV>
			</Repeater>
		</Template>
		<Template Name="Display">
				<CV Number="81" Type="Bit" Radiobits="15" Min="-" Max="-"  Low="-" High="-" Mode="rw" Radiovalues="0,1,2,3" Values="133">
					<Description Lang="de-DE" Text="Anzeige-Hardware"/>
					<Description Lang="en-EN" Text="Display-Hardware"/>
					<Bitdescription Bitnum="1" Lang="de-DE" Text="Kein Display angeschlossen"/>
					<Bitdescription Bitnum="1" Lang="en-EN" Text="no display connected"/>
					<Bitdescription Bitnum="2" Lang="de-DE" Text="20 LEDs (Portstatus)"/>
					<Bitdescription Bitnum="2" Lang="en-EN" Text="20 LEDs for Portstatus"/>
					<Bitdescription Bitnum="3" Lang="de-DE" Text="LCD DOGM163 16 x 3"/>
					<Bitdescription Bitnum="3" Lang="en-EN" Text="LCD DOGM163 16 x 3"/>
					<Bitdescription Bitnum="4" Lang="de-DE" Text="7-Segment LED ( vierstellig )"/>
					<Bitdescription Bitnum="4" Lang="en-EN" Text="7-Segment LED ( four digits )"/>
					<Bitdescription Bitnum="8" Lang="de-DE" Text="Ausgabe im Debug-Interface (FTDI)"/>
					<Bitdescription Bitnum="8" Lang="en-EN" Text="Output in Debug-Interface (FTDI)"/>
				</CV>
				<CV Number="82" Type="Radio" Min="-"  Max="-"  Low="-" High="-" Mode="rw" Radiovalues="0,1,2,3,4,5">
					<Description Lang="de-DE" Text="Angezeige Daten"/>
					<Description Lang="en-EN" Text="Shown data on Display"/>
					<Bitdescription Bitnum="1" Lang="de-DE" Text="Keine Daten anzeigen"/>
					<Bitdescription Bitnum="1" Lang="en-EN" Text="Don't show any data"/>
					<Bitdescription Bitnum="2" Lang="de-DE" Text="Modelbahnuhr"/>
					<Bitdescription Bitnum="2" Lang="en-EN" Text="Clock"/>
					<Bitdescription Bitnum="3" Lang="de-DE" Text="Messwert der Strecke aus CV83"/>
					<Bitdescription Bitnum="3" Lang="en-EN" Text="Result of one track from CV83"/>
					<Bitdescription Bitnum="4" Lang="de-DE" Text="Alle Messergebnisse"/>
					<Bitdescription Bitnum="4" Lang="en-EN" Text="All results"/>
					<Bitdescription Bitnum="5" Lang="de-DE" Text="Nur Portstatus"/>
					<Bitdescription Bitnum="5" Lang="en-EN" Text="Only status of ports"/>
					<Bitdescription Bitnum="6" Lang="de-DE" Text="Portstatus und Modelbahnuhr"/>
					<Bitdescription Bitnum="6" Lang="en-EN" Text="Status of ports and clock"/>
				</CV>
				<CV Number="83" Type="Bit" Radiobits="127" Min="-"  Max="-"  Low="-" High="-" Mode="rw" Radiovalues="0,1,2,3,4,5,6" Values="-">
					<Description Lang="de-DE" Text="Messstrecke wird in Display angezeigt. Bei CV82 = 2"/>
					<Description Lang="en-EN" Text="Measuringtrck which shown in display, If CV82 = 2"/>
					<Bitdescription Bitnum="1" Lang="de-DE" Text="Keine Messstrecke anzeigen"/>
					<Bitdescription Bitnum="1" Lang="en-EN" Text="Don't show any result"/>
					<Bitdescription Bitnum="2" Lang="de-DE" Text="Messstrecke 1"/>
					<Bitdescription Bitnum="2" Lang="en-EN" Text="Measuringtrack 1"/>
					<Bitdescription Bitnum="3" Lang="de-DE" Text="Messstrecke 2"/>
					<Bitdescription Bitnum="3" Lang="en-EN" Text="Measuringtrack 2"/>
					<Bitdescription Bitnum="4" Lang="de-DE" Text="Messstrecke 3"/>
					<Bitdescription Bitnum="4" Lang="en-EN" Text="Measuringtrack 3"/>
					<Bitdescription Bitnum="5" Lang="de-DE" Text="Messstrecke 4"/>
					<Bitdescription Bitnum="5" Lang="en-EN" Text="Measuringtrack 4"/>
					<Bitdescription Bitnum="6" Lang="de-DE" Text="Messstrecke 5"/>
					<Bitdescription Bitnum="6" Lang="en-EN" Text="Measuringtrack 5"/>
					<Bitdescription Bitnum="7" Lang="de-DE" Text="Messstrecke 6"/>
					<Bitdescription Bitnum="7" Lang="en-EN" Text="Measuringtrack 6"/>
					<Bitdescription Bitnum="8" Lang="de-DE" Text="In Massstab umrechnen: 0 = Nein, 1 = Ja"/>
					<Bitdescription Bitnum="8" Lang="en-EN" Text="Convert into Scale value: 0 = no, 1 = yes"/>
				</CV>
		</Template>
		<Template Name="MessParameter">
			<CV Number="84" Type="Byte" Min="-"  Max="-"  Low="-" High="-" Mode="rw" Values="-">
				<Description Lang="de-DE" Text="Massstab, z.B. HO = 87, TT = 120"/>
				<Description Lang="en-EN" Text="Scale: Example HO = 87, TT = 120"/>
			</CV>
			<CV Number="85" Type="Byte" Min="-"  Max="-"  Low="-" High="-" Mode="rw" Values="-">
				<Description Lang="de-DE" Text="Min. Zeit (ms) zwischen zwei Meldungen (debounce)"/>
			    <Description Lang="en-EN" Text="Min. time (ms) between two Occupance messages (debounce)"/>
			</CV>
			<CV Number="86" Type="Byte" Min="-"  Max="-"  Low="-" High="-" Mode="rw" Values="-">
				<Description Lang="de-DE" Text="Zeit (ms) zwischen den Portabfragen"/>
			    <Description Lang="en-EN" Text="time (ms) between port scan"/>
			</CV>
		</Template>
		<Template Name="ClockDisplayformat">
			<CV Number="87" Type="Bit" Min="-"  Max="-"  Low="-" High="-" Mode="rw" Values="3">
				<Description Lang="de-DE" Text="Format der Zeitanzeige"/>
			    <Description Lang="en-EN" Text="Displayformat of time"/>
				<Bitdescription Bitnum="1" Lang="de-DE" Text="Sprache für Wochentag, 0 = deutsch, 1 = englisch"/>
				<Bitdescription Bitnum="1" Lang="en-EN" Text="language for Weekday, 0 = german, 1 = english"/>
				<Bitdescription Bitnum="2" Lang="de-DE" Text="Zeitdarstellung Stunden, 0 = 24, 1 = 12 mit am/pm"/>
				<Bitdescription Bitnum="2" Lang="en-EN" Text="Format of hours, 0 = 24, 1 = 12 with am/pm"/>
			</CV>
		</Template>
		<Template Name="DisplayDOGM163">
			<CV Number="88" Type="Byte" Min="-"  Max="-"  Low="-" High="-" Mode="rw" Values="-">
				<Description Lang="de-DE" Text="ASCII-Code für Zeichen, wenn Belegtmelder frei ist."/>
				<Description Lang="en-EN" Text="ASCII-Code of character on OCC-Satutus 0 (free)"/>
			</CV>
			<CV Number="89" Type="Byte" Min="-"  Max="-"  Low="-" High="-" Mode="rw" Values="-">
				<Description Lang="de-DE" Text="ASCII-Code für Zeichen, wenn Belegtmelder belegt ist."/>
			    <Description Lang="en-EN" Text="ASCII-Code of character on OCC-Satutus 1"/>
			</CV>
		</Template>

	</Templates>
	<CVDefinition>
		<Node Offset="1" Template="About">
				<Nodetext Lang="de-DE" Text="Basis"/>
				<Nodetext Lang="en-EN" Text="Basis"/>
		</Node>
		<Node>
			<Nodetext Lang="de-DE" Text="Einstellungen der Anzeige"/>
			<Nodetext Lang="en-EN" Text="Settings for Display"/>
			<Node Offset="0" Template="Display">
				<Nodetext Lang="de-DE" Text="Externe Anzeige"/>
				<Nodetext Lang="en-EN" Text="Display"/>
			</Node>
			<Node Offset="0" Template="ClockDisplayformat">
				<Nodetext Lang="de-DE" Text="Zeitanzeige"/>
				<Nodetext Lang="en-EN" Text="Timepiece"/>
			</Node>			
			<Node Offset="0" Template="DisplayDOGM163">
				<Nodetext Lang="de-DE" Text="Einstellungen für DOGM163"/>
				<Nodetext Lang="en-EN" Text="Settings for DOGM163"/>
			</Node>
			
		</Node>
		<Node Template="OCC-Port" >
			<Nodetext Lang="de-DE" Text="Porteinstellungen"/>
			<Nodetext Lang="en-EN" Text="Portsettings"/>
		</Node>
		<Node Offset="0" Template="MessParameter">
			<Nodetext Lang="de-DE" Text="Parameter der Messung"/>
			<Nodetext Lang="en-EN" Text="Measering settings"/>
		</Node>
		<Node Offset="100" Template="Sector" Count="6" Next="5">
			<Nodetext Lang="de-DE" Text="Messstrecke %%d"/>
			<Nodetext Lang="en-EN" Text="Measuring track %%d"/>
		</Node>
	</CVDefinition>
</VendorCV>