com.ctc.wstx.cfg.OutputConfigFlags Maven / Gradle / Ivy
package com.ctc.wstx.cfg;
/**
* Constant interface that contains configuration flag used by output
* classes internally, for presenting on/off configuration options.
*/
public interface OutputConfigFlags
{
/**
* Flag that indicates whether writer is namespace-aware or not; if not,
* only local part is ever used.
*/
final static int CFG_ENABLE_NS = 0x0001;
/// Flag that indicates that output class should auto-generate namespace prefixes as necessary.
final static int CFG_AUTOMATIC_NS = 0x0002;
/// Flag that indicates we can output 'automatic' empty elements.
final static int CFG_AUTOMATIC_EMPTY_ELEMENTS = 0x0004;
/**
* Whether writer should just automatically convert all calls that
* would normally produce CDATA to produce (quoted) text.
*/
final static int CFG_OUTPUT_CDATA_AS_TEXT = 0x0008;
/**
* Flag that indicates whether attributes expanded from default attribute
* values should be copied to output, when using copy methods.
*/
final static int CFG_COPY_DEFAULT_ATTRS = 0x0010;
/**
* Flag that indicates whether CR (\r, ascii 13) characters occuring
* in text (CHARACTERS) and attribute values should be escaped using
* character entities or not. Escaping is needed to enable seamless
* round-tripping (preserving CR characters).
*/
final static int CFG_ESCAPE_CR = 0x0020;
/**
* Flag that indicates
* whether writer is to add a single white space before closing "/>"
* of the empty element or not. It is sometimes useful to add to
* increase compatibility with HTML browsers, or to increase
* readability.
*/
final static int CFG_ADD_SPACE_AFTER_EMPTY_ELEM = 0x0040;
/**
* Flag that indicates we can output 'automatic' empty elements;
* end elements needed to close the logical output tree when
* stream writer is closed (by closing it explicitly, or by writing
* end-document event)
*
* @since 3.2.8
*/
final static int CFG_AUTOMATIC_END_ELEMENTS = 0x0080;
/// Flag that indicates we should check validity of output XML structure.
final static int CFG_VALIDATE_STRUCTURE = 0x0100;
/**
* Flag that indicates we should check validity of textual content of
* nodes that have constraints.
*
* Specifically: comments can not have '--', CDATA sections can not
* have ']]>' and processing instruction can not have '?<' character
* combinations in content passed in.
*/
final static int CFG_VALIDATE_CONTENT = 0x0200;
/**
* Flag that indicates we should check validity of names (element and
* attribute names and prefixes; processing instruction names), that they
* contain only legal identifier characters.
*/
final static int CFG_VALIDATE_NAMES = 0x0400;
/**
* Flag that indicates we should check uniqueness of attribute names,
* to prevent accidental output of duplicate attributes.
*/
final static int CFG_VALIDATE_ATTR = 0x0800;
/**
* Flag that will enable writer that checks for validity of content
* to try to fix the problem, by splitting output segments as
* necessary. If disabled, validation will throw an exception; and
* without validation no problem is noticed by writer (but instead
* invalid output is created).
*/
final static int CFG_FIX_CONTENT = 0x1000;
/**
* Property that enables/disables stream write to close the underlying
* output target, either when it is asked to (.close() is called), or
* when it doesn't need it any more (reaching EOF, hitting an
* unrecoverable exception).
* As per Stax 1.0 specification, automatic closing is NOT enabled by
* default; except if the caller has no access to the target (i.e.
* when factory created it)
*/
final static int CFG_AUTO_CLOSE_OUTPUT = 0x2000;
}