models.10242.xml Maven / Gradle / Ivy
Go to download
Show more of this group Show more artifacts with this name
Show all versions of leshan-client-demo Show documentation
Show all versions of leshan-client-demo Show documentation
A demonstration client built upon the Leshan client.
<?xml version="1.0" encoding="UTF-8"?> <!-- BSD-3 Clause License Copyright 2019 Odins. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. 3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. --> <LWM2M xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://openmobilealliance.org/tech/profiles/LWM2M.xsd" > <Object ObjectType="MODefinition"> <Name>3-Phase Power Meter</Name> <Description1> <![CDATA[This Object provides the information to represent a generic 3-Phase Power Meter.]]> </Description1> <ObjectID>10242</ObjectID> <ObjectURN>urn:oma:lwm2m:x:10242</ObjectURN> <LWM2MVersion>1.0</LWM2MVersion> <ObjectVersion>1.0</ObjectVersion> <MultipleInstances>Multiple</MultipleInstances> <Mandatory>Optional</Mandatory> <Resources> <Item ID="0"> <Name>Manufacturer</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>String</Type> <RangeEnumeration/> <Units/> <Description> <![CDATA[Human readable manufacturer name]]> </Description> </Item> <Item ID="1"> <Name>Model Number</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>String</Type> <RangeEnumeration/> <Units/> <Description> <![CDATA[A model identifier (manufacturer specified string)]]> </Description> </Item> <Item ID="2"> <Name>Serial Number</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>String</Type> <RangeEnumeration/> <Units/> <Description> <![CDATA[Serial number of the meter]]> </Description> </Item> <Item ID="3"> <Name>Description</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>String</Type> <RangeEnumeration/> <Units/> <Description> <![CDATA[Description of the meter]]> </Description> </Item> <Item ID="4"> <Name>Tension R</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Mandatory</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>V</Units> <Description> <![CDATA[Voltage phase 1 (phase to neutral)]]> </Description> </Item> <Item ID="5"> <Name>Current R</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Mandatory</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>A</Units> <Description> <![CDATA[Current phase 1]]> </Description> </Item> <Item ID="6"> <Name>Active Power R</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kW</Units> <Description> <![CDATA[Active Power phase 1]]> </Description> </Item> <Item ID="7"> <Name>Reactive Power R</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kvar</Units> <Description> <![CDATA[Reactive Power phase 1]]> </Description> </Item> <Item ID="8"> <Name>Inductive Reactive Power R</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kvar</Units> <Description> <![CDATA[Inductive Reactive Power phase 1]]> </Description> </Item> <Item ID="9"> <Name>Capacitive Reactive Power R</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kvar</Units> <Description> <![CDATA[Capacitive Reactive Power phase 1]]> </Description> </Item> <Item ID="10"> <Name>Apparent Power R</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kVA</Units> <Description> <![CDATA[Apparent Power phase 1]]> </Description> </Item> <Item ID="11"> <Name>Power Factor R</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration>-1..1</RangeEnumeration> <Units/> <Description> <![CDATA[Power Factor phase 1]]> </Description> </Item> <Item ID="12"> <Name>THD-V R</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>/100</Units> <Description> <![CDATA[Total Harmonic Distortion phase 1 (Tension)]]> </Description> </Item> <Item ID="13"> <Name>THD-A R</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>/100</Units> <Description> <![CDATA[Total Harmonig Distortion phase 1 (Current)]]> </Description> </Item> <Item ID="14"> <Name>Tension S</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Mandatory</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>V</Units> <Description> <![CDATA[Voltage phase 2 (phase to neutral)]]> </Description> </Item> <Item ID="15"> <Name>Current S</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Mandatory</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>A</Units> <Description> <![CDATA[Current phase 2]]> </Description> </Item> <Item ID="16"> <Name>Active Power S</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kW</Units> <Description> <![CDATA[Active Power phase 2]]> </Description> </Item> <Item ID="17"> <Name>Reactive Power S</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kvar</Units> <Description> <![CDATA[Reactive Power phase 2]]> </Description> </Item> <Item ID="18"> <Name>Inductive Reactive Power S</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kvar</Units> <Description> <![CDATA[Inductive Reactive Power phase 2]]> </Description> </Item> <Item ID="19"> <Name>Capacitive Reactive Power S</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kvar</Units> <Description> <![CDATA[Capacitive Reactive Power phase 2]]> </Description> </Item> <Item ID="20"> <Name>Apparent Power S</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kVA</Units> <Description> <![CDATA[Apparent Power phase 2]]> </Description> </Item> <Item ID="21"> <Name>Power Factor S</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration>-1..1</RangeEnumeration> <Units/> <Description> <![CDATA[Power Factor phase 2]]> </Description> </Item> <Item ID="22"> <Name>THD-V S</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>/100</Units> <Description> <![CDATA[Total Harmonic Distortion phase 2 (Tension)]]> </Description> </Item> <Item ID="23"> <Name>THD-A S</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>/100</Units> <Description> <![CDATA[Total Harmonic Distortion phase 2 (Current)]]> </Description> </Item> <Item ID="24"> <Name>Tension T</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Mandatory</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>V</Units> <Description> <![CDATA[Voltage phase 3 (phase to neutral)]]> </Description> </Item> <Item ID="25"> <Name>Current T</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Mandatory</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>A</Units> <Description> <![CDATA[Current phase 3]]> </Description> </Item> <Item ID="26"> <Name>Active Power T</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kW</Units> <Description> <![CDATA[Active Power phase 3]]> </Description> </Item> <Item ID="27"> <Name>Reactive Power T</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kvar</Units> <Description> <![CDATA[Reactive Power phase 3]]> </Description> </Item> <Item ID="28"> <Name>Inductive Reactive Power T</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kvar</Units> <Description> <![CDATA[Inductive Reactive Power phase 3]]> </Description> </Item> <Item ID="29"> <Name>Capacitive Reactive Power T</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kvar</Units> <Description> <![CDATA[Capacitive Reactive Power phase 3]]> </Description> </Item> <Item ID="30"> <Name>Apparent Power T</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kVA</Units> <Description> <![CDATA[Apparent Power phase 3]]> </Description> </Item> <Item ID="31"> <Name>Power Factor T</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration>-1..1</RangeEnumeration> <Units/> <Description> <![CDATA[Power Factor phase 3]]> </Description> </Item> <Item ID="32"> <Name>THD-V T</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>/100</Units> <Description> <![CDATA[Total Harmonic Distortion phase 3 (Tension)]]> </Description> </Item> <Item ID="33"> <Name>THD-A T</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>/100</Units> <Description> <![CDATA[Total Harmonic Distortion phase 3 (Current)]]> </Description> </Item> <Item ID="34"> <Name>3-Phase Active Power</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kW</Units> <Description> <![CDATA[3-Phase Active Power]]> </Description> </Item> <Item ID="35"> <Name>3-Phase Reactive Power</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kvar</Units> <Description> <![CDATA[3-Phase Reactive Power]]> </Description> </Item> <Item ID="36"> <Name>3-Phase Inductive Reactive Power</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kvar</Units> <Description> <![CDATA[3-Phase Inductive Reactive Power]]> </Description> </Item> <Item ID="37"> <Name>3-Phase Capacitive Reactive Power</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kvar</Units> <Description> <![CDATA[3-Phase Capacitive Reactive Power]]> </Description> </Item> <Item ID="38"> <Name>3-Phase Apparent Power</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kVA</Units> <Description> <![CDATA[3-Phase Apparent Power]]> </Description> </Item> <Item ID="39"> <Name>3-Phase Power Factor</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration>-1..1</RangeEnumeration> <Units/> <Description> <![CDATA[3-Phase Power Factor]]> </Description> </Item> <Item ID="40"> <Name>3-Phase phi cosine</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration>-1..1</RangeEnumeration> <Units/> <Description> <![CDATA[3-Phase phi cosine]]> </Description> </Item> <Item ID="41"> <Name>Active Energy</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kWh</Units> <Description> <![CDATA[Active Energy]]> </Description> </Item> <Item ID="42"> <Name>Reactive Energy</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kvarh</Units> <Description> <![CDATA[Reactive Energy]]> </Description> </Item> <Item ID="43"> <Name>Inductive Reactive Energy</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kvarh</Units> <Description> <![CDATA[Inductive Reactive Energy]]> </Description> </Item> <Item ID="44"> <Name>Capacitive Reactive Energy</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kvarh</Units> <Description> <![CDATA[Capacitive Reactive Energy]]> </Description> </Item> <Item ID="45"> <Name>Apparent Energy</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>kVAh</Units> <Description> <![CDATA[Apparent Energy]]> </Description> </Item> <Item ID="46"> <Name>Tension R-S</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>V</Units> <Description> <![CDATA[Voltage phase 1 to phase 2]]> </Description> </Item> <Item ID="47"> <Name>Tension S-T</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>V</Units> <Description> <![CDATA[Voltage phase 2 to phase 3]]> </Description> </Item> <Item ID="48"> <Name>Tension T-R</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>V</Units> <Description> <![CDATA[Voltage phase 3 to phase 1]]> </Description> </Item> <Item ID="49"> <Name>Frequency</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>Hz</Units> <Description> <![CDATA[Frequency]]> </Description> </Item> <Item ID="50"> <Name>Neutral Current</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration/> <Units>A</Units> <Description> <![CDATA[Neutral Current]]> </Description> </Item> </Resources> <Description2/> </Object> </LWM2M>