All Downloads are FREE. Search and download functionalities are using the official Maven repository.

models.10243.xml Maven / Gradle / Ivy

There is a newer version: 2.0.0-M15
Show newest version
<?xml version="1.0" encoding="UTF-8"?>

<!-- BSD-3 Clause License

Copyright 2019 Odins. 
Redistribution and use in source and binary forms, with or without
modification, are permitted provided that the following conditions
are met:
1. Redistributions of source code must retain the above copyright
notice, this list of conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright
notice, this list of conditions and the following disclaimer in the
documentation and/or other materials provided with the distribution.
3. Neither the name of the copyright holder nor the names of its
contributors may be used to endorse or promote products derived
from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
"AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
-->

<LWM2M xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://openmobilealliance.org/tech/profiles/LWM2M.xsd" >
<Object ObjectType="MODefinition">
    <Name>Single-Phase Power Meter</Name>
    <Description1>
        <![CDATA[This Object provides the information to represent a generic Single-Phase Power Meter.]]>
    </Description1>
    <ObjectID>10243</ObjectID>
    <ObjectURN>urn:oma:lwm2m:x:10243:2.0</ObjectURN>
    <LWM2MVersion>1.0</LWM2MVersion>
	<ObjectVersion>2.0</ObjectVersion>
    <MultipleInstances>Multiple</MultipleInstances>
    <Mandatory>Optional</Mandatory>
    <Resources>
        <Item ID="0">
            <Name>Manufacturer</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>String</Type>
            <RangeEnumeration/>
            <Units/>
            <Description>
                <![CDATA[Human readable manufacturer name]]>
            </Description>
        </Item>
        <Item ID="1">
            <Name>Model Number</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>String</Type>
            <RangeEnumeration/>
            <Units/>
            <Description>
                <![CDATA[A model identifier (manufacturer specified string)]]>
            </Description>
        </Item>
        <Item ID="2">
            <Name>Serial Number</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>String</Type>
            <RangeEnumeration/>
            <Units/>
            <Description>
                <![CDATA[Serial number of the meter]]>
            </Description>
        </Item>
        <Item ID="3">
            <Name>Description</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>String</Type>
            <RangeEnumeration/>
            <Units/>
            <Description>
                <![CDATA[Description of the meter]]>
            </Description>
        </Item>
        <Item ID="4">
            <Name>Tension</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Mandatory</Mandatory>
            <Type>Float</Type>
            <RangeEnumeration/>
            <Units>V</Units>
            <Description>
                <![CDATA[Voltage]]>
            </Description>
        </Item>
        <Item ID="5">
            <Name>Current</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Mandatory</Mandatory>
            <Type>Float</Type>
            <RangeEnumeration/>
            <Units>A</Units>
            <Description>
                <![CDATA[Current]]>
            </Description>
        </Item>
        <Item ID="6">
            <Name>Active Power</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>Float</Type>
            <RangeEnumeration/>
            <Units>kW</Units>
            <Description>
                <![CDATA[Active Power]]>
            </Description>
        </Item>
        <Item ID="7">
            <Name>Reactive Power</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>Float</Type>
            <RangeEnumeration/>
            <Units>kvar</Units>
            <Description>
                <![CDATA[Reactive Power]]>
            </Description>
        </Item>
        <Item ID="8">
            <Name>Inductive Reactive Power</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>Float</Type>
            <RangeEnumeration/>
            <Units>kvar</Units>
            <Description>
                <![CDATA[Inductive Reactive Power]]>
            </Description>
        </Item>
        <Item ID="9">
            <Name>Capacitive Reactive Power</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>Float</Type>
            <RangeEnumeration/>
            <Units>kvar</Units>
            <Description>
                <![CDATA[Capacitive Reactive Power]]>
            </Description>
        </Item>
        <Item ID="10">
            <Name>Apparent Power</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>Float</Type>
            <RangeEnumeration/>
            <Units>kVA</Units>
            <Description>
                <![CDATA[Apparent Power]]>
            </Description>
        </Item>
        <Item ID="11">
            <Name>Power Factor</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>Float</Type>
            <RangeEnumeration>-1..1</RangeEnumeration>
            <Units/>
            <Description>
                <![CDATA[Power Factor]]>
            </Description>
        </Item>
        <Item ID="12">
            <Name>THD-V</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>Float</Type>
            <RangeEnumeration/>
            <Units>/100</Units>
            <Description>
                <![CDATA[Total Harmonic Distortion (Tension)]]>
            </Description>
        </Item>
        <Item ID="13">
            <Name>THD-A</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>Float</Type>
            <RangeEnumeration/>
            <Units>/100</Units>
            <Description>
                <![CDATA[Total Harmonic Distortion (Current)]]>
            </Description>
        </Item>
        <Item ID="14">
            <Name>Active Energy</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>Float</Type>
            <RangeEnumeration/>
            <Units>kWh</Units>
            <Description>
                <![CDATA[Active Energy]]>
            </Description>
        </Item>
        <Item ID="15">
            <Name>Reactive Energy</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>Float</Type>
            <RangeEnumeration/>
            <Units>kvarh</Units>
            <Description>
                <![CDATA[Reactive Energy]]>
            </Description>
        </Item>
        <Item ID="16">
            <Name>Apparent Energy</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>Float</Type>
            <RangeEnumeration/>
            <Units>kVAh</Units>
            <Description>
                <![CDATA[Apparent Energy]]>
            </Description>
        </Item>
        <Item ID="17">
            <Name>Frequency</Name>
            <Operations>R</Operations>
            <MultipleInstances>Single</MultipleInstances>
            <Mandatory>Optional</Mandatory>
            <Type>Float</Type>
            <RangeEnumeration/>
            <Units>Hz</Units>
            <Description>
                <![CDATA[Frequency]]>
            </Description>
        </Item>
    </Resources>
    <Description2/>
</Object>
</LWM2M>




© 2015 - 2024 Weber Informatics LLC | Privacy Policy