models.3423.xml Maven / Gradle / Ivy
Go to download
Show more of this group Show more artifacts with this name
Show all versions of leshan-client-demo Show documentation
Show all versions of leshan-client-demo Show documentation
A demonstration client built upon the Leshan client.
<?xml version="1.0" encoding="UTF-8"?> <!-- BSD-3 Clause License Copyright 2020 uCIFI Alliance Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. 3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. --> <LWM2M xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://openmobilealliance.org/tech/profiles/LWM2M.xsd"> <Object ObjectType="MODefinition"> <Name>Gas meter</Name> <Description1>The uCIFI gas meter measures the volume of gas that was distributed through the gas meter, in pulse count and/or in m3. It also detects anomalies in the gas meter.</Description1> <ObjectID>3423</ObjectID> <ObjectURN>urn:oma:lwm2m:ext:3423</ObjectURN> <LWM2MVersion>1.0</LWM2MVersion> <ObjectVersion>1.0</ObjectVersion> <MultipleInstances>Multiple</MultipleInstances> <Mandatory>Optional</Mandatory> <Resources> <Item ID="1"> <Name>Cumulated gas volume</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Mandatory</Mandatory> <Type>Float</Type> <RangeEnumeration></RangeEnumeration> <Units>m3</Units> <Description>Number of cubic meters of gas distributed through the meter since last reset.</Description> </Item> <Item ID="2"> <Name>Cumulated gas meter value reset</Name> <Operations>E</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type></Type> <RangeEnumeration></RangeEnumeration> <Units></Units> <Description>Reset the cumulated meter value.</Description> </Item> <Item ID="3"> <Name>Type of meter</Name> <Operations>RW</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>String</Type> <RangeEnumeration></RangeEnumeration> <Units></Units> <Description>Type of gas meter.</Description> </Item> <Item ID="4"> <Name>Cumulated pulse value</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Integer</Type> <RangeEnumeration></RangeEnumeration> <Units></Units> <Description>Cumulated number of pulses detected on the gas meter.</Description> </Item> <Item ID="5"> <Name>Cumulated pulse value reset</Name> <Operations>E</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type></Type> <RangeEnumeration></RangeEnumeration> <Units></Units> <Description>Reset the cumulated pulse value.</Description> </Item> <Item ID="6"> <Name>Pulse ratio</Name> <Operations>RW</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Integer</Type> <RangeEnumeration></RangeEnumeration> <Units></Units> <Description>Ratio to calculate gas volume from pulse value.</Description> </Item> <Item ID="7"> <Name>Minimum flow rate</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration></RangeEnumeration> <Units>m3/s</Units> <Description>Minimum flow rate since last metering value.</Description> </Item> <Item ID="8"> <Name>Maximum flow rate</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration></RangeEnumeration> <Units>m3/s</Units> <Description>Maximum flow rate since last metering value.</Description> </Item> <Item ID="9"> <Name>Leak suspected</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Boolean</Type> <RangeEnumeration></RangeEnumeration> <Units></Units> <Description>Set to True if gas leak is suspected.</Description> </Item> <Item ID="10"> <Name>Leak detected</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Boolean</Type> <RangeEnumeration></RangeEnumeration> <Units></Units> <Description>Set to True if gas leak is detected.</Description> </Item> <Item ID="11"> <Name>High temperature</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Boolean</Type> <RangeEnumeration></RangeEnumeration> <Units></Units> <Description>Set to True if high temperature is detected around the gas meter.</Description> </Item> </Resources> <Description2></Description2> </Object> </LWM2M>