models.3427.xml Maven / Gradle / Ivy
Go to download
Show more of this group Show more artifacts with this name
Show all versions of leshan-client-demo Show documentation
Show all versions of leshan-client-demo Show documentation
A demonstration client built upon the Leshan client.
<?xml version="1.0" encoding="UTF-8"?> <!-- BSD-3 Clause License Copyright 2020 uCIFI Alliance Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. 3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. --> <LWM2M xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://openmobilealliance.org/tech/profiles/LWM2M.xsd"> <Object ObjectType="MODefinition"> <Name>Pressure monitoring sensor</Name> <Description1>The uCIFI water pressure monitoring sensor measures water pressure and help identify water leaks in water distribution pipelines.</Description1> <ObjectID>3427</ObjectID> <ObjectURN>urn:oma:lwm2m:ext:3427</ObjectURN> <LWM2MVersion>1.0</LWM2MVersion> <ObjectVersion>1.0</ObjectVersion> <MultipleInstances>Multiple</MultipleInstances> <Mandatory>Optional</Mandatory> <Resources> <Item ID="1"> <Name>Pressure</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Mandatory</Mandatory> <Type>Float</Type> <RangeEnumeration></RangeEnumeration> <Units>Pa</Units> <Description>Last or current pressure value measured by the sensor.</Description> </Item> <Item ID="2"> <Name>Sampling period</Name> <Operations>RW</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Integer</Type> <RangeEnumeration></RangeEnumeration> <Units>s</Units> <Description>Number of seconds between two measurement.</Description> </Item> <Item ID="3"> <Name>Leak detected</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Boolean</Type> <RangeEnumeration></RangeEnumeration> <Units></Units> <Description>Set to True if a water leak is detected by the sensor.</Description> </Item> <Item ID="4"> <Name>Hammer effect detected</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Boolean</Type> <RangeEnumeration></RangeEnumeration> <Units></Units> <Description>Set to True if hammer effect is detected in the water pipeline.</Description> </Item> <Item ID="5"> <Name>Minimum measured pressure value</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration></RangeEnumeration> <Units>Pa</Units> <Description>Minimum value measured by the sensor since power ON or reset.</Description> </Item> <Item ID="6"> <Name>Maximum measured pressure value</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration></RangeEnumeration> <Units>Pa</Units> <Description>Maximum value measured by the sensor since power ON or reset.</Description> </Item> <Item ID="7"> <Name>Minimum range pressure value</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration></RangeEnumeration> <Units>Pa</Units> <Description>Minimum value that can be measured by the sensor.</Description> </Item> <Item ID="8"> <Name>Maximum range pressure value</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration></RangeEnumeration> <Units>Pa</Units> <Description>Maximum value that can be measured by the sensor.</Description> </Item> <Item ID="9"> <Name>Reset min and max measured pressure values</Name> <Operations>E</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type></Type> <RangeEnumeration></RangeEnumeration> <Units></Units> <Description>Set the minimum and maximum measured values to current value.</Description> </Item> </Resources> <Description2></Description2> </Object> </LWM2M>