models.3326.xml Maven / Gradle / Ivy
Go to download
Show more of this group Show more artifacts with this name
Show all versions of leshan-server-demo Show documentation
Show all versions of leshan-server-demo Show documentation
A LWM2M demonstration server running an embedded Jetty server
<?xml version="1.0" encoding="utf-8"?> <LWM2M xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://openmobilealliance.org/tech/profiles/LWM2M.xsd"> <Object ObjectType="MODefinition"> <Name>Acidity</Name> <Description1>This IPSO object should be used to report an acidity measurement of a liquid. It also provides resources for minimum and maximum measured values, as well as the minimum and maximum range that can be measured by the sensor. An example measurement unit is pH. </Description1> <ObjectID>3326</ObjectID> <ObjectURN>urn:oma:lwm2m:ext:3326</ObjectURN> <MultipleInstances>Multiple</MultipleInstances> <Mandatory>Optional</Mandatory> <Resources> <Item ID="5700"> <Name>Sensor Value</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Mandatory</Mandatory> <Type>Float</Type> <RangeEnumeration></RangeEnumeration> <Units>Defined by “Units” resource.</Units> <Description>Last or Current Measured Value from the Sensor</Description> </Item> <Item ID="5701"> <Name>Sensor Units</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>String</Type> <RangeEnumeration></RangeEnumeration> <Units></Units> <Description>Measurement Units Definition e.g. “Cel” for Temperature in Celsius</Description> </Item> <Item ID="5601"> <Name>Min Measured Value</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration></RangeEnumeration> <Units>Defined by “Units” resource.</Units> <Description>The minimum value measured by the sensor since power ON or reset</Description> </Item> <Item ID="5602"> <Name>Max Measured Value</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration></RangeEnumeration> <Units>Defined by “Units” resource.</Units> <Description>The maximum value measured by the sensor since power ON or reset</Description> </Item> <Item ID="5603"> <Name>Min Range Value</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration></RangeEnumeration> <Units>Defined by “Units” resource.</Units> <Description>The minimum value that can be measured by the sensor</Description> </Item> <Item ID="5604"> <Name>Max Range Value</Name> <Operations>R</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>Float</Type> <RangeEnumeration></RangeEnumeration> <Units>Defined by “Units” resource.</Units> <Description>The maximum value that can be measured by the sensor</Description> </Item> <Item ID="5605"> <Name>Reset Min and Max Measured Values</Name> <Operations>E</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type></Type> <RangeEnumeration></RangeEnumeration> <Units></Units> <Description>Reset the Min and Max Measured Values to Current Value</Description> </Item> <Item ID="5821"> <Name>Current Calibration</Name> <Operations>RW</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>String</Type> <RangeEnumeration></RangeEnumeration> <Units></Units> <Description>Read or Write the current calibration coefficient</Description> </Item> <Item ID="5750"> <Name>Application Type</Name> <Operations>RW</Operations> <MultipleInstances>Single</MultipleInstances> <Mandatory>Optional</Mandatory> <Type>String</Type> <RangeEnumeration></RangeEnumeration> <Units></Units> <Description>The application type of the sensor or actuator as a string depending on the use case</Description> </Item> </Resources> <Description2></Description2> </Object> </LWM2M>