operationaltemplate.ehrbase_blood_pressure_simple.de.v0.opt Maven / Gradle / Ivy
The newest version!
ISO_639-1
en
Not Specified
Initial
Template metadata sample set
ISO_639-1
en
Not Specified
369de4c1-fa55-49ee-9f85-2dd8bc21f6e9
ehrbase_blood_pressure_simple.de.v0
ehrbase_blood_pressure_simple.de.v0
COMPOSITION
true
true
false
false
1
1
at0000
category
true
true
false
false
1
1
DV_CODED_TEXT
true
true
false
false
1
1
defining_code
true
true
false
false
1
1
CODE_PHRASE
true
true
false
false
1
1
openehr
433
context
true
true
false
false
0
1
EVENT_CONTEXT
true
true
false
false
1
1
other_context
true
true
false
false
0
1
ITEM_TREE
true
true
false
false
1
1
at0001
items
true
true
false
false
0
1
CLUSTER
true
true
false
false
0
1
at0006
items
true
true
false
false
1
1
CLUSTER
true
false
true
0
at0000
items
true
true
false
false
1
1
ELEMENT
true
true
false
false
0
1
at0001
value
true
true
false
false
0
1
DV_TEXT
true
true
false
false
1
1
ELEMENT
true
true
false
false
0
1
at0002
value
true
true
false
false
0
1
DV_TEXT
true
true
false
false
1
1
CLUSTER
true
true
false
false
0
1
at0004
items
true
true
false
false
1
1
ELEMENT
true
true
false
false
0
1
at0003
value
true
true
false
false
0
1
DV_TEXT
true
true
false
false
1
1
ELEMENT
true
true
false
false
0
1
at0005
value
true
true
false
false
0
1
DV_TEXT
true
true
false
false
1
1
ELEMENT
true
true
false
false
0
1
at0006
value
true
true
false
false
0
1
DV_TEXT
true
true
false
false
1
1
false
false
true
false
true
0
CLUSTER
true
true
false
false
0
1
at0007
items
true
true
false
false
1
1
CLUSTER
true
false
true
0
Boolean
2007
false
String
- archetype_id/value
attribute
C_STRING
-
openEHR-EHR-CLUSTER\.device\.v1
constraint
false
false
true
false
true
0
CLUSTER
true
true
false
false
0
1
at0008
items
true
true
false
false
1
1
ELEMENT
true
true
false
false
0
1
at0009
value
true
true
false
false
0
1
DV_DATE_TIME
true
true
false
false
1
1
ELEMENT
true
true
false
false
0
1
at0010
value
true
true
false
false
0
1
DV_DATE_TIME
true
true
false
false
1
1
ELEMENT
true
true
false
false
0
1
at0011
value
true
true
false
false
0
1
DV_TEXT
true
true
false
false
1
1
false
false
true
false
true
0
false
false
true
false
true
0
openEHR-EHR-CLUSTER.sample_device.v1
The details of the device used
Device details (training sample)
The name of the device
Name
Description of the device
Description
The name of the manufacturer
Manufacturer
Information about the manufacture of the device
Manufacturer details
The model of the device
Model
The serial number of the device
Serial number
Information about the device components
Components
Details of servicing
Servicing
The date the device was last serviced
Date last serviced
Date the device was last calibrated
Date last calibration
Agent performed the servicing
Serviced by
false
false
true
false
true
0
false
false
true
false
true
0
content
true
true
false
false
0
1
OBSERVATION
true
true
false
false
1
8
at0000
data
true
true
false
false
1
1
HISTORY
true
true
false
false
1
1
at0001
events
true
true
false
false
0
1
POINT_EVENT
true
true
false
false
0
1
at0002
offset
true
true
false
false
1
1
DV_DURATION
true
true
false
false
1
1
value
true
true
false
false
1
1
DURATION
true
true
false
false
1
1
-
true
true
false
false
PT0S
PT0S
data
true
true
false
false
1
1
ITEM_LIST
true
true
false
false
1
1
at0003
items
true
true
false
false
0
1
ELEMENT
true
true
false
false
0
1
at0004
value
true
true
false
false
0
1
DV_QUANTITY
true
true
false
false
1
1
openehr
125
true
false
false
false
0
1000
true
true
false
false
0
0
mm[Hg]
ELEMENT
true
true
false
false
0
1
at0005
value
true
true
false
false
0
1
DV_QUANTITY
true
true
false
false
1
1
openehr
125
true
false
false
false
0
1000
true
true
false
false
0
0
mm[Hg]
ELEMENT
true
true
false
false
0
1
at1006
value
true
true
false
false
0
1
DV_QUANTITY
true
true
false
false
1
1
openehr
125
true
true
false
false
0
750
true
true
false
false
1
1
mm[Hg]
ELEMENT
true
true
false
false
0
1
at1007
value
true
true
false
false
0
1
DV_QUANTITY
true
true
false
false
1
1
openehr
125
true
true
false
false
0
750
true
true
false
false
0
0
mm[Hg]
ELEMENT
true
true
false
false
0
1
at0033
value
true
true
false
false
0
1
DV_TEXT
true
true
false
false
1
1
true
false
true
false
true
0
state
true
true
false
false
0
1
ITEM_TREE
true
true
false
false
1
1
at0007
items
true
true
false
false
0
1
ELEMENT
true
true
false
false
1
1
at0008
value
true
true
false
false
0
1
DV_CODED_TEXT
true
true
false
false
1
1
defining_code
true
true
false
false
1
1
CODE_PHRASE
true
true
false
false
1
1
local
at1001
local
at1000
at1001
at1002
at1003
at1013
at1014
CLUSTER
true
false
true
0
at1030
Boolean
2007
false
String
- archetype_id/value
attribute
C_STRING
-
openEHR-EHR-CLUSTER\.sample_level_of_exertion\.v1
constraint
ELEMENT
true
true
false
false
0
1
at1005
value
true
true
false
false
0
1
DV_QUANTITY
true
true
false
false
1
1
0
°
0
openehr
497
true
true
false
false
-90
90
true
true
false
false
0
0
°
true
false
true
false
true
0
false
false
true
false
true
1
protocol
true
true
false
false
0
1
ITEM_TREE
true
true
false
false
1
1
at0011
items
true
true
false
false
0
1
ELEMENT
true
true
false
false
0
1
at0013
value
true
true
false
false
0
1
DV_CODED_TEXT
true
true
false
false
1
1
defining_code
true
true
false
false
1
1
CODE_PHRASE
true
true
false
false
1
1
local
at0015
at0016
at0017
at1008
at1009
at1018
at1019
ELEMENT
true
true
false
false
0
1
at0014
value
true
true
false
false
0
1
DV_CODED_TEXT
true
true
false
false
1
1
defining_code
true
true
false
false
1
1
CODE_PHRASE
true
true
false
false
1
1
local
at0025
at0026
at0027
at0028
at0032
at1020
at1021
at1026
at1031
at1032
ELEMENT
true
true
false
false
0
1
at1010
value
true
true
false
false
0
1
DV_CODED_TEXT
true
true
false
false
1
1
defining_code
true
true
false
false
1
1
CODE_PHRASE
true
true
false
false
1
1
local
at1011
at1012
CLUSTER
true
false
true
0
at1025
Boolean
2007
false
String
- archetype_id/value
attribute
C_STRING
-
openEHR-EHR-CLUSTER\.device\.v1
constraint
true
false
true
false
true
0
openEHR-EHR-OBSERVATION.sample_blood_pressure.v1
The measurement of arterial blood pressure which is deemed to be a surrogate
for arterial pressure in the systemic circulation.
Blood pressure (Training sample)
history Structural node
history
Baseline event in event history
Baseline reading
@ internal @
blood pressure
Peak systemic arterial blood pressure over one cycle - measured in systolic
or contraction phase of the heart cycle
Systolic
Minimum systemic arterial blood pressure over one cycle - measured in the
diastolic or relaxation phase
Diastolic
Other event in event history
any event
@ internal @
state structure
The position of the person at the time of measuring blood pressure
Position
list structure
list structure
The size of the cuff used for blood pressure measurement
Cuff size
The site of the measurement of the blood pressure
Location of measurement
A cuff that is standard for an adult - bladder approx 13cm x 30cm
Adult
A cuff for adults with larger arms - bladder approx 16cm x 38cm
Large Adult
A cuff that is appropriate for a child or thin arm - bladder approx 8cm x 21
cm
Paediatric/Child
The right arm of the person
Right arm
The left arm of the person
Left arm
The right thigh of the person
Right thigh
The left thigh of the person
Left thigh
Blood pressure reading after 5 minutes rest
5 minute reading
Blood pressure reading after 10 minutes rest
10 minute reading
The difference between standing and sitting/lying blood pressure
Postural change
Blood pressure monitored via an intra-arterial line
Intra-arterial
Comment on blood pressure reading
Comment
Standing at the time of blood pressure measurement
Standing
Sitting (for example on bed or chair) at the time of blood pressure
measurement
Sitting
Reclining at the time of blood pressure measurement
Reclining
Lying flat at the time of blood pressure measurement
Lying
Variation in blood pressure with respiration
Paradox
The tilt of the surface on which the person is lying
Tilt
The average arterial pressure that occurs over the entire course of the
heart contraction and relaxation cycle. In non-invasive blood pressure measurements the MAP is
calculated using (2 x Systolic Blood Pressure + Diastolic Blood Pressure) divided by 3.
Mean Arterial Pressure
The difference between the systolic and diastolic pressure over one
contraction cycle.
Pulse Pressure
A cuff used for an adult thigh - bladder approx 20cm x 42 cm
Adult Thigh
A cuff used for a new born - bladder approx 3cm x 6cm
Neonatal
Record which Korotkoff sound is used for determining diastolic pressure
Korotkoff sounds
The fourth Korotkoff sound is identified as an abrupt muffling of sounds
Fourth sound
The fifth Korotkoff sound is identified by absence of sounds as the cuff
pressure drops below the diastolic blood pressure
Fifth sound
Lying flat on the back (supine position) with the feet higher than the head
at the time of blood pressure measurement
Trendelenburg
Lying on the left side at the time of blood pressure measurement
Left Lateral
A cuff used for infants - bladder approx 5cm x 15cm
Infant
A cuff used for a small adult - bladder approx 10cm x 24 cm
Small Adult
The right wrist of the person
Right wrist
The left wrist of the person
Left wrist
Details about sphygmomanometer or other device used to measure the blood
pressure
Device
A finger of the person
Finger
Details about physical activity undertaken as the blood pressure is
recorded
Level of Exertion
The right ankle of the person
Right ankle
The left ankle of the person
Left ankle
SNOMED-CT(2003)
163020007
SNOMED-CT(2003)
163030003
SNOMED-CT(2003)
163031004
SNOMED-CT(2003)
246153002
false
false
true
false
true
0
openEHR-EHR-COMPOSITION.sample_encounter.v1
ehrbase_blood_pressure_simple.de.v0
Generic encounter or progress note composition
Encounter (training sample)
@ internal @
Tree
*
Admin detail
*
Admin detail
© 2015 - 2025 Weber Informatics LLC | Privacy Policy