schematron.cda_phmr.templates.2.16.840.1.113883.10.20.9.14.ent Maven / Gradle / Ivy
The newest version!
HL7 PHMR Results Section - errors validation phase
Error: A Results Section is a section element in the HL7 V3 namespace. See Section 3.2.
Error: A Results Section SHALL contain the LOINC code 30954-2. See Section 3.2, Section 3.3.3, and Table 2.
Error: CONF-PHMR-57: A Results section SHALL contain two templateIds. CCD
templateId 2.16.840.1.113883.10.20.1.14 SHALL be present and the section
SHALL conform to all the constraints specified in CCD for that template. An
additional templateId SHALL be present where the value of @root is
2.16.840.1.113883.10.20.9.14, indicating conformance to the constraints
specified in this DSTU.
Error: CONF-PHMR-60: If no results are recorded, this section SHALL contain a text
element noting this fact.
HL7 PHMR Results Section - warning validation phase
Warning: CONF-PHMR-58: One or more Numeric Organizers (templateId
2.16.840.1.113883.10.20.9.8) SHOULD be present inside entry elements.
HL7 PHMR Results Section - notes validation phase
Note: CONF-PHMR-59: One or more Waveform Series Organizers (templateId
2.16.840.1.113883.10.20.9.12) MAY be present inside entry elements.