    HL7 PHMR Numeric Observation - errors validation phase
    

    
    Error: CONF-PHMR-102: A Numeric Observation SHALL be represented with an observation
    element where @classCode is OBS and @moodCode is EVN.
    

    
    Error: CONF-PHMR-105: A code element SHALL be present where @codeSystem is
    2.16.840.1.113883.6.96 SNOMED CT (DYNAMIC) or 2.16.840.1.113883.6.24
    MDC (DYNAMIC).
    

    
    Error: CONF-PHMR-106: A value element SHALL be present where @xsi:type is PQ (physical
    quantity) and the unit of measure is expressed using a valid Unified Code for Units
    of Measure (UCUM) expression.
    

    

  

  

  
    HL7 PHMR Numeric Observation - warning validation phase

    

    
    Warning: CONF-PHMR-107: A participant element SHOULD be present conforming to the
    constraints of a PHMR Product Instance Reference.
    

    

  

  

  

    HL7 PHMR Numeric Observation - notes validation phase


  