schematron.hitspc37_20080211.templates.1.3.6.1.4.1.19376.1.3.1.ent Maven / Gradle / Ivy
The newest version!
Error: A leaf section of the structuredBody shall contain one entry containing the machine-readable result data rendered in the section.
Error: The section/entry typeCode value is "DRIV".
Error: The entry/templateId root value shall be 1.3.6.1.4.1.19376.1.3.1 and the extension shall be "Lab.Report.Data.Processing.Entry".
Error: The section/entry shall contain an act element with classCode="ACT" and moodCode="EVN".
Error: The act/classCode shall be "ACT" and the act/moodCode shall be "EVN" for a laboratory report.
Error: the act/statusCode code value shall be completed, active, aborted, or obsolete.
Error: The act/confidentialityCode code value shall be "R" or "V".
Error: The entry/act shall have at least one entryRelationship containing the content for an Isolate, Battery or Observation
Error the entry/act/entryRelationship shall have a typeCode of "COMP".
Error: The specimen typeCode shall be "SPC".
Error: The specimen/specimenRole classCode shall be "SPEC" or "ISLT".
Error: The specimen/specimenRole/specimenPlayingEntity shall be present.
Error: The specimen/specimenRole/specimenPlayingEntity shall be present.
Error:The specimenRole/productOf typeCode shall be "PRD".
Error:The specimenRole/productOf/procedure classCode shall be "PROC".
Error:The specimenRole/productOf/procedure moodCode shall be "EVN".
Error: The / /performer typeCode shall be "PRF".
Error: the / /performer/assignedEntity classCode shall be "ASSIGNED".
Error: The / /performer/assignedEntity shall have an address
Error: The / /performer/assignedEntity shall have a telecom
Error: A / /performer/assignedEntity/representedOrganization element shall have a name.
Error: The / /author typeCode shall be "AUT".
Error: the / /author/assignedAuthor classCode shall be "ASSIGNED".
Error: The / /author/assignedAuthor/id element shall have attributes @extension and @root.
Error: An entry/act/author/assignedAuthor element shall contain at least one assignedPerson or assignedAuthoringDevice element.
Error: The / /author/assignedAuthor shall have an address
Error: The / /author/assignedAuthor shall have a telecom
Error: The non-blank name element shall be present for / /author/assignedAuthor/assignedPerson or the author/assignedAuthor/assignedAuthoringDevice shall have a softwareName.
Error: The entry/act/author/assignedAuthor shall have an representedOrganization element.
Error: The typeCode for / /participant shall be "VRF", "RESP" or "DEV".
Error: The / /participant/participantRole shall exist with attribute classCode value = "ASSIGNED".
Error: The / /participant/participantRole shall have an id.
Error: The / /participant/participantRole shall have an address.
Error: The / /participant/participantRole shall have a telecom
Error: The / /playingEntity appears only when participant typeCode equals "RESP" or "VRF".
Error: The / /playingEntity shall have a name element.
Error: The / /playingDevice appears only when participant typeCode equals "DEV".
Error: The / /playingDevice shall have a code element.
Error: The / /playingDevice shall have a manufacturerModelName element.
Error: The entry/act/entryRelationship/organizer shall have a moodCode of "EVN" and classCode of "CLUSTER" or "BATTERY". The classCode "CLUSTER"
represents a SpecimenObservationCluster_Organizer and the classCode "BATTERY" represeents a Battery_Organizer.
Error: The entry/act/entryRelationship/organizer/statusCode shall be completed, aborted, or obsolete.
Error: The organizer element of an SpecimenObservationCluster_Organizer shall have one or more component elements
Error: The entry/act/entryRelationship/organizer shall have a specimen node for a SpecimenObservationCluster_Organizer.
Error: The entry/act/Relationship/organizer shall have a specimen node with specimenRole classCode = "ISLT".
Error: An observation shall have the values classCode = "OBS" and moodCode = "EVN".
Error: The observation/statusCode shall be completed, aborted, or obsolete.
Error: The observation/code shall identify the unique test code in an international standard (LOINC or SNOMED CT) or a national standard.
Error: The component/observation/referenceRange shall have a typeCode value "REFV".
Error: The component/observation/referenceRange shall have the values classCode = "OBS" and moodCode = "EVN.CRT".
Error: The component/observation/referenceRange shall have an interpretationCode.
Error: The component/observation/referenceRange/precondition shall have a typeCode value "PRCN".
Error: The component/observation/referenceRange shall have the values classCode = "OBS" and moodCode = "EVN".
Warning: The entry/observationMedia is only required to support small image formats gif, jpeg, png, or bmp. Readability at the target may depend on using only these formats.
Warning: A multimedia object shall be encoded in BASE 64.
Warning: A / /performer/time/low element used to represent a time interval should have a value.
Warning: A / /performer/time/high element used to represent a time interval should have a value.
Warning: A / /performer/assignedEntity should have a non-blank addr element.
Warning: A / /performer/assignedEntity telecom element should have a value.
Warning: A / /performer/assignedEntity/assignedPerson should have a non-blank name element.
Warning: A / /author/time/low element used to represent a time interval should have a value.
Warning: A / /author/time/high element used to represent a time interval should have a value.
Warning: A / /author/assignedAuthor should have a non-blank addr element.
Warning: A / /author/assignedAuthor telecom element should have a value.
Warning: A / /participant/participantRole should have a non-blank addr element.
Warning: A / /participant/participantRole telecom element should have a value.
Note: This entry/act/code is the unique code from which the section/code is derived.
Note: entry/act/entryRelationship/organizer/id represents the lab filler order number for this battery.
Note: entry/act/entryRelationship/organizer/code is the unique code for the battery in the appropriate vocabulary.
Note: The entry/act/entryRelationship typeCode may equal "COMP". This indicates an Annotation_Act having an act sub-element.
The comment is delivered by the text sub-element if it is purely textual or a code sub-element for a coded comment.
Note: The entry/act/entryRelationship typeCode may equal "REFR". This indicates an observation complemented by any number
of previous results as pertinent information.
Note: The entry/act/entryRelationship typeCode may equal "REFR". A sequenceNumber element should be included with a
number of 1 or greater.
Note: If all observations of the entry have been produced on the same specimen thenthat specimen
SHALL be attached to the Report_Entry through a subject participation represented by a specimen element.
Note: If all observations of the entry have been produced on the same specimen than that speciment
SHALL be attached to the Report_Entry through a subject participation represented by a specimen element.
Note:The SpecimenObservationCluster can have any number of Battery_Organizers or Observations.
Note: An observation may have a specimen if it does not inherit this relationship from an upper level.
Note: An observation may have an interpretationCode.
Note: An observation may have an effectiveTime. See table 4.4.-4 Structure of Observation.
Note: An observation may have a value which is the result obtained for the test using the appropriate value. See table 4.4.-4 Structure of Observation.
Note: An obervation may have a methodCode. See table 4.4.-4 Structure of Observation.